
27
Ec Controller
LCD display shows Err.
15.
The automatic circuit
breaker has detected an
electrical problem.
The Err in the display indicates a short
circuit or electrical overload on a
particular station. The stations number
should also be displayed. For example,
2 Err means the problem is in the
circuit for Station 2.
Usually, the short circuit is in the
solenoid on the electric valve, but shorts
can also occur in the wire connectors at
the valve. Occasionally, nicked or
skinned field wires can cause a short.
A large pump start relay can also
produce a momentary overload that may
be detected by the controller.
Locate and repair the cause of the short
circuit. See Diagnostic Circuit Breaker
on p. 6 for instructions on clearing the
problem indicator from the display and
testing the station.
LCD display shows Err for a
few seconds and then shows
the station operating for a few
seconds.
16.
Same as Cause #15.
See correction for Cause #15.
SYMPTOM
POSSIBLE CAUSE
CORRECTION
Summary of Contents for E-6C
Page 1: ...G B F E Espa ol 29 Fran ais 57 English 2...
Page 9: ...9 Ec Controller...
Page 11: ...11 Ec Controller...
Page 28: ...28 Ec Controller Notes...
Page 29: ......
Page 30: ......
Page 31: ......