4
PRR S-2 Turbine Operating Instructions
PROTOSMOKE™ UNIT OPERATION
The S-2 Turbine contains a self-powered smoke unit that outputs a steady stream of smoke
through the smoke stack on the roof of the engine. The ON/OFF switch located next to the
trailing truck must be in the ON position in order for the smoke unit to function. See Fig.
3 below.
The smoke unit is essentially a small heating
element and wick which soaks up and then “cooks" a
mineral oil-based fluid that omits a harmless smoke.
The smoke is then forced out of the stack via a small
electric fan which runs at a constant speed. However,
the smoke intensity can be varied by increasing the
transformer voltage setting. The higher the setting,
the more intense the smoke output.
For best results, we recommend that you add 15 -
20 drops of ProtoSmoke™, Seuthe, LGB or LVTS
fluid before you run the engine. If you don’t choose
to add the fluid, then the smoke unit switch should
be turned off. Failure to either add the fluid or turn the switch off could lead to damage to the
smoke unit heating element and or wicking. Add the fluid through the smoke stack hole. After
adding the fluid, gently blow into the stack to eliminate any air bubbles. Do not overfill the
unit as overfilling can cause the fluid to leak out and coat the interior engine components.
When the smoke output begins to diminish while running the engine, an additional 10-15
drops of smoke fluid should be added or the smoke unit switch should be turned off. When
storing the engine for long periods of time, you may want to add at least 15 drops of fluid to
keep the wick soaked with fluid and prevent it from drying out. After removing the engine
from storage, it is advisable to add another 25 drops of fluid, letting the wick soak up the fluid
for 15 minutes prior to operation.
MAINTENANCE
CAUTION:
Operating the engine without smoke fluid
and with the smoke unit switch in the ON position can
damage your smoke unit wick, causing the wick to
become hard, blackened and unabsorbant around the
heating element. When this occurs, it may be difficult
for the wick to soak up the smoke fluid resulting in
poor or no smoke output. If that occurs, we
recommend that you inspect and/or replace the wick
taking care to not run the engine without fluid in the
future. You can inspect the wick to see if it needs
replacement by removing the smoke unit inspection
cover from the body as seen in Fig.4. After removing
the chassis and inspection cover screws lift the
inspection plate away and inspect the wick. If the wick
is darkly discolored and hard, it should be replaced.
Smoke Unit
ON/OFF Switch
Figure 3: Smoke Unit Switch
Smoke Unit
Circuit Board
Mounting Screws
Smoke Unit Frame
Mounting Screws
Figure 4: Inspecting The Smoke Unit