background image

Lost or Unknown Engine Address and the 55-55-55 Address Reset

In some cases you may not remember or have somehow lost the engine address. 
Following the above Feature or Factory Resets will allow you to recover an engine. The 
limitation to this is that for most resets you must know the engine address. If you are 
unsure of the engine address you can apply the 55-55-55 reset (send a value of 55 to CV55 
to engine address 55). In order for this to work correctly the engine's address must NOT 
be 55. The engine will need to be sitting at some address other than 55.

Below is the method (55-55-55 Reset) you can employ to return an engine to its factory 
default short address of 3 (it will also set the engine's long address back to its default – 
usually 3333 or the cab number on some models) if you're unsure of the engine's current 
address:

Check first to see if the engine happens to be sitting at address 55. Call up engine 55 

on your DCC handheld and hit F3 to start the engine up. If it starts up then you 
can change the address to whatever you want using CV1 (short address) or CV17 and 
CV18 (long address)

If the engine doesn't start up at address 55 then you can use the 55-55-55 reset. To 

perform this follow the instructions below:

Ensure the DCC system is powered up and power is on the rails

Call up engine address 55. NOTE – you are NOT changing the engine's 

address to 55 you are just telling the DCC system to start talking to engine 
address 55. You will want to make sure that no other MTH engines are on 
the rails or any other manufacturer's engines with an address of 55 are on 
the rails. MTH engines will listen for commands coming to engine address 
55 when the 55-55-55 reset is enabled even though they are not 
programmed as address 55

Enter PoM mode on your DCC handheld and write a value of 55 to 

CV55. Again, even though your MTH engine is NOT on address 55 it will 
still listen for this reset command

Call up address 3 on your DCC handheld and hit F3. The engine should 

now start-up

If you have performed the 55-55-55 reset and the engine still doesn't respond then place 
the engine on the programming track output of your DCC system and program a value 
of 3 to CV1. This will set the engine's short address to 3. However, as long as the engine 
is NOT programmed as address 55 then the 55-55-55 reset will always set the engine's 
long and short addresses back to their factory defaults. It will also set the engine's 
addressing back to short (if you happened to have CV29 set to long addressing)

The 55-55-55 Reset can be confusing at first but the main point to note is that you are 
NOT setting the engine's address to 55 to perform the reset, you are just calling up 
engine address 55 on your DCC handheld and sending a value of 55 to CV55. Again, 
MTH engine's will listen to the 55-55-55 reset command even though the engine's address 
isn't actually 55 (and it can't be for the 55-55-55 reset to work).

RailKing 4-8-8-4 Big Boy Steam Engine

24

Summary of Contents for 4-8-8-4

Page 1: ...rack system including M T H s RealTrax or ScaleTrax or traditional tubular track It is also compatible with most standard AC transformers See pages 46 and 47 for a complete list of compatible transfor...

Page 2: ...of Contents Before you Begin 3 Set Up Checklist 3 Lubrication 3 Priming the Smoke Unit 3 Placing Engine On Track 4 PS 3 0 Enhancements 6 Conventional AC DC Start up Shut down 6 DCC Switch 6 Programmin...

Page 3: ...from squeaking Use light household oil and follow the lubrication points marked L in Fig 1 Do not over oil Use only a drop on each pivot point Priming the Smoke Unit When preparing to run this engine...

Page 4: ...bar is connected to the engine chassis with a screw and should not need any attention Optional Long Drawbar is required for O 31 operation In order to mate the connectors of the drawbar and the tender...

Page 5: ...ilment where the engine or the tender would turn over and the other unit would remain upright If the drawbar is not properly connected your engine may exhibit erratic or no operation If this happens t...

Page 6: ...me ONLY applies to conventional AC track power Once the headlight shuts off the engine will play its start up sounds and all the lights will come back on simultaneously Smoke too if you have it turned...

Page 7: ...OTE Requires a TIU w version 4 20 or later firmware and requires Consumer Loader version 2 30 or later LED Lighting Gone are the incandescent bulbs Your new PS3 0 equipped engine has LED lighting MTH...

Page 8: ...ard and speed will increase as the throttle is advanced If there is another interruption in track power the sequence will change to the neutral position again The engine will remain in the neutral sta...

Page 9: ...e Bell button To turn the bell off press and release the Bell button again The bell will continue to ring from the time you turn it on until you press and release the button again to turn it off Horn...

Page 10: ...ion Reset to Factory Defaults 1 Bell 1 Horn Whistles 1 Bell 2 Horn Whistles 1 Bell 3 Horn Whistles 1 Bell 4 Horn Whistles 1 Horn Whistle 2 Bells from Neutral only 1 Horn Whistle 3 Bells 1 Horn Whistle...

Page 11: ...train will not move as you use the Direction button to trigger the sounds Proto Sound 3 0 has disabled operator control over the Horn and Bell buttons until the full PFA sequence is complete After wai...

Page 12: ...upler Horn Bell Horn Horn Fire Front Coupler Horn Horn Bell Tips on Using PFA You can terminate PFA at any time by turning off power to the track for 15 seconds You do not have to be in Forward to use...

Page 13: ...urn it to the other condition You will want to do this during the initial neutral upon start up if you ever couple this engine to another engine that is not equipped with speed control to avoid damagi...

Page 14: ...A sounds cannot be initiated in conventional DC Only the engine sounds smoke squealing brakes and idle sounds will function Operation of your MTH Proto Sound 3 0 engine in conventional DC is very simi...

Page 15: ...to the engine at start up the engine will not move This is normal We refer to this as Anti Jackrabbit and this feature prevents your model from taking off at high track voltages Simply lower the trac...

Page 16: ...control station manufacturer s manual for more information on how they handle F Function buttons Your MTH PS3 0 equipped engine s default short address is 3 So all you have to do is power up your DCC...

Page 17: ...egin ringing 2 Slowly reduce the throttle until the train stops at the desired location and speed reaches zero Press the F4 button twice toggle F4 on then off again and the bell will stop ringing You...

Page 18: ...erse Signal Pressing F10 twice toggling on then off will sound the Reverse Signal This is three whistle horn blasts Grade Crossing Signal Again just like a real engine you can trigger the Grade Crossi...

Page 19: ...ing on then off The Extended Shut Down is very similar to F3 in that the engine will ultimately shut down but in the case of Extended Shut Down you will hear the crew talking back and forth about how...

Page 20: ...to add realism F24 Single Whistle Horn Blast To play a Single Horn Blast press the F24 button twice toggling in on then off This plays a single short horn blast F26 Brake Sounds Pressing the F26 butto...

Page 21: ...ard Signal Reverse Signal Grade Crossing Smoke On Off Smoke Volume Idle Sequence 3 Idle Sequence 2 Idle Sequence 1 Extended Start Up Extended Shut Down Labor Chuff Drift Chuff One Shot Doppler Coupler...

Page 22: ...rt DCC address The default Short address is always 3 The default Long address will be 3333 To change your engine s Short Address using PoM 1 Call up the engine s current address on your DCC handheld 2...

Page 23: ...han 5 seconds may result in losing the setting changes If all else fails and you aren t sure of something never fear You can always get your engine back to a known state by either performing a Feature...

Page 24: ...u are just telling the DCC system to start talking to engine address 55 You will want to make sure that no other MTH engines are on the rails or any other manufacturer s engines with an address of 55...

Page 25: ...1 F8 for the active consist Defines active functions for FL and F9 F12 for the active consist bit 0 1 will tell an engine that you want it s FL control to operate under the consist address bit1 0 bit2...

Page 26: ...ternate Speed Curve Step 23 Alternate Speed Curve Step 24 Alternate Speed Curve Step 25 Alternate Speed Curve Step 26 Alternate Speed Curve Step 27 Alternate Speed Curve Step 28 Reverse Trim User ID 1...

Page 27: ...number IS NOT the F Function number you d use on your DCC handheld It is used internally in the engine SOUNDS Bell Brake Sounds Cab Chatter Clickety Clack Coupler Close Coupler Slack Drift Chuff Engin...

Page 28: ...your DCC controller The engine will give you a two horn blast indication Note You ve also left an empty location where PFA used to be F4 5 Now you can fill that location with whichever CV you d like F...

Page 29: ...CV19 set to 0 Setting the MSB Bit 7 of CV19 tells the engine that it is facing reverse in the consist Setting CV21 and CV22 determine which F Functions the consist responds to See diagram below for e...

Page 30: ...engine s address Most systems have a light bulb icon to indicate whether F0 is active or not Ensure that it is OFF 5 Call up the Rear engine on your DCC handheld address 3 in this example 6 Set CV19 t...

Page 31: ...u to set which F Functions you want the consist address to control For example you will likely want all of your MTH consist engines to respond to Start Up Shut Down F3 Also you ll likely want at your...

Page 32: ...amming Track differ it is recommended that you use a DCC Programming Track Booster to perform functions on the programming track Simply put try to program or read back the address of an MTH engine on...

Page 33: ...mple CV29 you would simply add the additional bits you enabled to the existing value to obtain the new CV value For example if you had a consist address CV19 set to 5 and you wanted to alter this to s...

Page 34: ...onal grease until after 50 hours of operation or one year whichever comes first To access the gear box and axles do the following 1 Turn the engine upside down 2 Remove the boiler by removing the body...

Page 35: ...n cloth on the rails Thereafter keep an eye on the track and clean it when it gets dirty to ensure good electrical contact and to lengthen the life of the tires Clean any type of track with this heavy...

Page 36: ...with a 5mm nutdriver Clean the groove using a cotton swab and denatured alcohol Make sure the old tire has been completely removed from the groove in the drive wheel using a razor blade or small flat...

Page 37: ...ockwise Position located under the tender body Failure either to add fluid to the unit or to turn it off may damage the smoke unit heating element and or wicking material When the smoke output while r...

Page 38: ...y not be sending enough power to the track to power the engine Rotate throttle clockwise to increase track power Coupler Solution When I try to fire the coupler PFA starts The Proto Coupler won t let...

Page 39: ...engine doesn t go into reverse When the PFA enters its last sequence the bell automatically comes on When PFA is enabled pressing the whistle and bell has no effect I push the direction button but the...

Page 40: ...der Full CW Max volume Check to see if a screw or some other material hasn t lodged itself in the underside of the chassis or tender Make sure smoke volume pot is turned full CW Make sure smoke volume...

Page 41: ...pply power to the track my engine starts up lights and sound but it won t move My engine hesitates at slow speeds Lower the track voltage then raise it again The engine should start moving If you appl...

Page 42: ...ress the F21 button again to turn Doppler off Your engine sounds will now return to normal Check to see if a screw or some other material hasn t lodged itself in the underside of the engine Smoke Solu...

Page 43: ...ing This is normal dial up the speed on your DCC controller to make your engine move PFA Solution I hit F4 to start the PFA but the engine just keeps ringing its bell that s all it ll do Bring the eng...

Page 44: ...again to turn Doppler off Your engine sounds will now return to normal When I apply power to the track my engine doesn t do anything No lights no sound I get an error when I hit Start Up DCS is polar...

Page 45: ...by itself after the PFA is over Press the DIR button Your engine will stop and begins the arrival sequence Pressing the DIR button will cycle you through the next 3 PFA sequences This is normal The e...

Page 46: ...0 Watt Standard Lionel 1063 Lionel LW Powermaster U A U A U A 8 17v 8 18v 8 18v 60 Watt 75 Watt 135VA Standard Standard Electronic All Trol Left Terminal Right Terminal 0 24v 300 Watt Electronic Dalle...

Page 47: ...1 18VDC on Supply 0 18VDC at Controller 240 Watt Electronic MRC 6200 0 18 5v 60 Watt Electronic Not Recommended For 70 3001 1 J3a Not recommended for 70 3001 1 J3a RECOMMENDED DC TRANSFORMERS Notes On...

Page 48: ...Proto Sound 3 0 engines but does not turn off the input power to the TIU One Touch Global Mute UnMute Single button mutes or unmutes all DCS controlled locomotives sounds Proto Dispatch Operation Publ...

Page 49: ...vice Centers If you need assistance at any time email MTH Service at service mth railking com or call 410 381 2580 Limited One Year Warranty All M T H products purchased from an M T H Authorized Retai...

Reviews: