2. Cannot make connection between thermometer and receiver

- Possible Reasons

1) Bluetooth on receiver might be switched off or in error.   
2) iFertracker might not run or in error.   
3) Out of connection range.   
4) Already connect with another receiver.

- Solutions

1) Open Bluetooth on receiver.   
2) Run iFertracker.
3) Put thermometer close to receiver or on the top of the screen of receiver.
4) Please check other receivers

if any of them connected, disconnect and connect 

targeting receiver.

3. No temperature data uploaded

- Possible Reasons

1) Did not sync time with receiver after uploading a new battery.

2) Measuring duration is too short.   3) Contacted area of skin is not flat and smooth.   

4) Low battery power.   5) Accidentally connect with receiver during wearing time, 
already uploaded data.

- Solutions

1) Open iFertracker App on receiver and connect receiver with thermometer to sync 
time.
2) Please keep measuring more than 3 hours.

3) Please adjust wearing position.

4) Please replace battery.
5) We suggest to turn off receiver or turn off Bluetooth on receiver during wearing.

Summary of Contents for WT702

Page 1: ...Wireless Thermometer WT702 User Manual Temperature Probe Battery Compartment Raiing Medical Company...

Page 2: ...fection 17 Technical Specifications 18 Functional Description 19 Symbol Definition 20 Disclaimer 21 Declaration 21 Copyright Statement Accessories 1 A CR2025 battery 2 A battery tool 3 Medical sticker...

Page 3: ...battery compartment 2 Upload a CR2025 battery 3 Close battery compartment Download App 1 Go to iFertracker Download Center http www raiing com iFertracker download php 2 Download iFertracker and set u...

Page 4: ...ermal environment is recommended Please make sure wear the thermometer during whole night whole sleeping period to get accurate data If you feel unwell uncomfortable or Allergic when use the sticker p...

Page 5: ...successfully powers on LED long brightness indicates battery low and cannot continues to work please change with new button cell 3 Frequently operating modes Connect to receiver for the first time to...

Page 6: ...iFertracker will automatically connect thermometer to sync data and then analyze Recommendation user should connect thermometer with receiver every day after taking off thermometer to get information...

Page 7: ...connected disconnect and connect targeting receiver 3 No temperature data uploaded Possible Reasons 1 Did not sync time with receiver after uploading a new battery 2 Measuring duration is too short 3...

Page 8: ...rate 6 Soaking device in liquid or disinfectant may lead to incorrect data or break the device 7 Do not press the device If the housing is broken please stop using the device 8 Please pay attention to...

Page 9: ...dult It can be used in hospital and at home Not used in ICU and other emergency condition Maintenance 1 Please replace the battery when the low battery indication appears otherwise the device will not...

Page 10: ...ice 4 If you notice any deterioration or damage to probe stop using the device immediately Cleaning Disinfection Product Name Wireless Thermometer Model WT702 Size 55 6mm 31 6mm 6 5mm Weight 6g withou...

Page 11: ...syncing data every time 2 Low voltage indication There is a dialogue box on receiver when a low battery 2 7V device connected with the receiver Symbol Definition Read user manual before use Recyclable...

Page 12: ...e Bluetooth word mark figure mark combination mark and Bluetooth Smart and Bluetooth Smart Ready marks are all trademarks that are owned by the Bluetooth SIG and any use of such marks by Raiing is und...

Page 13: ...Product Name Model Manufacturer Registration Address Manufacture Address Service Tel Email...

Reviews: