ToxiRAE Pro PID 

QuickStart Guide 

 

 

 

 
 
 
 
 
 
 
 
 
 

 

RAE Systems, Inc. 

 

 

3775 N. First St. 

 

 

San Jose, CA 95134-1708 USA 

 

WARNINGS 

Read Before Operating

 

The ToxiRAE Pro PID User’s Guide must be 
carefully read by all individuals who have or will 
have the responsibility of using, maintaining, or 
servicing this product. The product will perform as 
designed only if it is used, maintained, and serviced 
in accordance with the manufacturer’s instructions. 

 

CAUTION! 

Never operate the monitor when the cover is 
removed. Remove monitor top cap, rear cover, and 
battery only in an area known to be non-hazardous. 
 

User Interface 

 

The ToxiRAE Pro PID’s user interface consists of 
the display, four LED lights, an alarm buzzer, and 
two keys, [MODE] and [Y/+].   The LCD displays 
real-time reading in specified measurement units, sensor 
type, alarm type (when in alarm, including cal. or bump 
overdue), Man Down status, battery status, datalog (if on), 
and radio and connection quality (if available). 

 

 
 
 
 

Charging The ToxiRAE Pro PID 

 

Always fully charge the battery before use. Contacts on 
the bottom of the ToxiRAE Pro PID meet the cradle’s 
contact pins, transferring power. While charging, the 
LED on the cradle glows red. When the battery is fully 
charged, the LED glows green. 

 

 

 

Turning The ToxiRAE Pro PID On 

 

Press and hold [MODE] for 3 seconds. During 
startup, the battery, buzzer, vibration alarm, and 
LEDs are tested, and then the ToxiRAE Pro PID 
performs self-testing of its functions. When the 
main measurement screen appears, the ToxiRAE 
Pro PID is ready for calibration or use. 

 
Note: 

If the battery is almost fully discharged, the 

message “Battery too low! Needs charging. 
Powering off!” shows in the display and the 
ToxiRAE Pro PID shuts off. You must charge the 
battery before you can use the instrument. 
 

 

Turning The ToxiRAE Pro PID Off 

 

Press and hold [MODE]. A 5-second countdown to 
shutoff begins. You must continue pressing on the 
key for the entire shutoff process. If you remove 
your finger from the key during the countdown, the 
shutoff operation is canceled and the ToxiRAE Pro 
PID continues normal operation. 
 
When the countdown beeps stop and you see “Unit 
Off,” release your finger from the [MODE] key. 
The ToxiRAE Pro PID is now off. 

 

 

Belt clip (on back) 

Alarm 
Buzzer 

LEDs 

Display 

 

[MODE] key 

[Y/+] key 

2. 

3. 

5. 

6. 

4. 

 

Gas inlet 

LED 

Place ToxiRAE 
Pro PID in 
charging cradle 

Connect AC 
adapter to charging  
cradle and 
plug it into AC 
power source 

Latch 
release 

Raised lip 
locks into  
cradle’s 
latch 

Charging 
status LED 

Phone: 

408-952-8200      

Fax: 

408-952-8480 

Email:

 [email protected] 

www.raesystems.com 

Reviews: