background image

Model DL-ATG Operating Instructions 

P/N 889-4300-00 

 

MODEL DL-ATG 

 

TWO CHANNEL ANTI-TAILGATING LOOP DETECTOR 

OPERATING INSTRUCTIONS 

 

General 

The model designation indicates the number of lanes covered by each loop. 

Model DL-ATG-x

 

 

1

 = Single Lane 

 

 

 

= Two Lane 

The Model DL-ATG is a two channel detector designed to accurately count vehicles and identify their direction of travel over two 
small inductive loops,  even if they are tailgating.  Please note that the Model DL-ATG has been specifically designed and tested to 
count and/or identify 

passenger vehicles

The Model DL-ATG accumulates directional vehicle counts that are displayed on the front panel Liquid Crystal Display (LCD).  The 
Model DL-ATG has 4 relay outputs; 2 for loop presence, 1 for counting in the AB direction, and 1 for counting in the BA direction. 

Prior to initial operation, the Model DL-ATG detector must be calibrated

.  Connect the detector to an appropriately wired harness 

and apply power.  Follow the instructions outlined under 

Calibration 

on page 2 to calibrate the detector. 

II 

Controls 

Push Buttons 

 

 B Count 

When pressed the LCD screen displays the number of vehicles that have traveled over the loops in the A

B direction.  This 

accumulator is capable of accumulating up to 99,999 directional counts.  The display will show the hundreds, tens, and ones digits 
until the accumulated count exceeds 999.  At this point the display will alternate between the ten thousands and thousands digits and 
the remaining three digits for hundreds, tens, and ones. Loss of power will not reset this number. The A

B accumulator is indicated 

by 

the     symbol on the bottom of the LCD screen. 

 

 A Count 

When pressed the LCD screen displays the number of vehicles that have traveled over the loops in the B

A direction.  This 

accumulator is capable of accumulating up to 99,999 directional counts.  The display will show the hundreds, tens, and ones digits 
until the accumulated count exceeds 999.  At this point the display will alternate between the ten thousands and thousands digits and 
the remaining three digits for hundreds, tens, and ones. Loss of power will not reset this number. The B

A accumulator is indicated 

by 

the  symbol on the bottom of the LCD screen. 

 

Count Reset 

When pressed, both A

B and B

A Count accumulators are reset to zero. 

Loop Fail 

When pressed, the LCD screen displays the count of past failures for each loop.  The LCD will display the text “LOOP FAIL” and a 

channel indicator icon 

 for Channel A or 

 for Channel B. These numbers reset to 0 for both channels on power down, or when 

Detector Reset is pressed. 

Diagnostics

 

When pressed the LCD screen continuously displays the Loop Inductance value L= in microhenries (µH).  When a vehicle is detected 
the LCD displays the percentage of inductance change -

ΔL/L= value.  When this feature is activated a single audible beep sounds for 

vehicles traveling in the A

B direction.  A double audible beep sounds for vehicles in the B

A direction.  Pressing the Diagnostics 

button again while viewing Diagnostics will toggle between Channel A and Channel B.  This Diagnostic display will turn OFF after 
15 minutes and return to the A

B Count display.  

Detector Reset 

When pressed both channels are reset.  Detector Reset will clear the loop fail accumulators, and any prior loop fail indication.  
Detector Reset does not reset the count accumulators. 

3510 E. Atlanta Ave. 

Phoenix, AZ 85040 USA 

Telephone: (480) 968-6407 

Fax: (602) 437-1996 

Website: www.editraffic.com 

E-mail: [email protected] 

 

 

Summary of Contents for DL-ATG

Page 1: ...een B A Count When pressed the LCD screen displays the number of vehicles that have traveled over the loops in the B A direction This accumulator is capable of accumulating up to 99 999 directional counts The display will show the hundreds tens and ones digits until the accumulated count exceeds 999 At this point the display will alternate between the ten thousands and thousands digits and the rem...

Page 2: ... loop has been detected over both channels and there is no presence detected on the loops for approximately five 5 seconds Once the calibration process has successfully been completed the display will revert from CAL to Count A B Please note that once the calibration process has been initiated there is no way to cancel the calibration procedure To enter into calibration mode after initial calibrat...

Page 3: ...een B A Count When pressed the LCD screen displays the number of vehicles that have traveled over the loops in the B A direction This accumulator is capable of accumulating up to 99 999 directional counts The display will show the hundreds tens and ones digits until the accumulated count exceeds 999 At this point the display will alternate between the ten thousands and thousands digits and the rem...

Page 4: ...ation loop has been detected over both channels and there is no presence detected on the loops for approximately five 5 seconds Once the calibration process has successfully been completed the display will revert from CAL to Count A B Please note that once the calibration process has been initiated there is no way to cancel the calibration procedure To enter into calibration mode after initial cal...

Reviews: