889-3809-00
Model 2018 Operations Manual Rev Apr 2020 Page
18
of 41
Dual Indication Monitoring
: Green-Yellow Dual Indication Reset time is changed from 300
milliseconds to 100 milliseconds. Green-Red Dual Indication Reset time is changed from 300
milliseconds to 100 milliseconds.
Typical Use
: This feature is intended to support the use of flashing Green indications as used in Canada.
2.6.3.2
FAST START UP
Configuration:
This is a factory option and cannot be changed by the user. If this function is required but it is not
active, contact Reno A&E Technical Support for assistance. This feature is set to OFF for all units unless
specifically requested to be turned on when ordered. NOTE: The same effect can be achieved by holding in the
front panel Reset switch while the monitor is powered up.
Operations Modified:
Monitor Power Up / Power Recovery
: When Fast Start Up is enabled, the four second delay is
removed and replaced with actual boot time (approximately 800 milliseconds). Also, if operating in
the 2010 mode of operation, the requirement for five watchdog transitions before exiting start up flash
is removed. Five watchdog transitions must still be detected before the ten second max power up
timer expires.
Typical Use
: Some agencies prefer that the monitor power up as fast as possible and allow normal operation of the
intersection as soon as possible to minimize flash time, especially if the monitor is plugged in while the
intersection is already running. Without this feature, the monitor will always take at least four seconds to power up
and allow normal operation of the intersection. With this feature, the start up flash time will be less than one
second.
2.6.3.3
LOW AC POWER THRESHOLDS
Configuration:
This is a factory option and cannot be changed by the user. If this function is required but it is not
active, contact Reno A&E Technical Support for assistance. This feature is set to OFF for all units unless
specifically requested to be turned on when ordered.
Operations Modified:
Monitor Power Up / Power Recovery
: When Low AC Power Thresholds is enabled, the valid AC
voltage threshold is changed from 103V
RMS
to 98V
RMS
.
Monitor Power Failure
: When Low AC Power Thresholds is enabled, the invalid AC voltage
threshold is changed from 98V
RMS
to 92V
RMS
.
Typical Use
: Some agencies prefer the lower AC power thresholds especially in areas with chronic low voltage
issues.
2.6.3.4
DIAGNOSTIC LCD
Configuration:
This is a factory option and cannot be changed by the user. If this function is required but it is not
active, contact Reno A&E Technical Support for assistance. This feature is set to OFF for all units.
Operations Modified:
Diagnostic LCD
: The monitor is capable of driving a special 4 line by 40 character diagnostic display.
This display can display any of over 40 diagnostic screens. The active screen is selected using Option
Switches 3 through 8. When this feature is enabled, any changes to these six Option Switches will not
cause configuration changes, only change the active diagnostic screen. The state of the Option
Switches prior to the activation of this feature will be used until this feature is turned off.
Typical Use
: Troubleshooting of monitor issues by factory personnel.
2.6.4
SOFTWARE OPTIONS
2.6.4.1
LOG FIELD CHANGES
Configuration:
This is a feature that can only be modified through the use of the RaeComM software and a
computer or laptop. In the RaeComM software click on the wrench icon or on the menu choose Config / Monitor
Configuration. This feature is on the Electronic Options tab and in the Software Option box in the lower right.
This feature is set to OFF at the factory.
Operations Modified:
Signal Sequence Log
: When Log Field Changes is enabled, the Signal Sequence log will change from
recording the state and voltage on every input every 33 milliseconds to checking every 33
milliseconds to see if the state of any input changed. The Watchdog input will not be included in the