3.7.2
Installing the Standard Mounting Kit on a Horizontal Pole
1. Remove the mounting
kit from the ODU
packaging box.
2. Loosen both M8X90 Hex
Head Screws by rotating
both M8 Flange Nuts until
the end of the Hex Head
Screw.
3. Remove the M8 Flange
Nut from the M8X40 Hex
Head Screw.
4. Place the ODU Vertical
Adapter on the M8X40
Hex Head Screw.
5. Tighten the M8 Flange
Nut with a torque of 15
Nm until the mounting kit
is firmly on the ODU.
7. Insert the ODU Vertical
Adapter into the ODU
hole. Tighten the M8
Flange Nut with a torque
of 15 Nm until the
mounting kit is firmly on
the ODU.