background image

 

 

 
 

Manual number 

PTI-12-03/01/07/A

 

 
 

 

 

Integrated system for counting pieces and labelling 

 

WLT/L series 
WLL series 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

 

 

 

MANUFACTURER OF ELECTRONIC WEIGHING INSTRUMENTS 

 

RADWAG,  26 – 600 Radom, Bracka 28 Street 
POLAND 
phone +48 48 38 48 800, phone/fax. +48 48 385 00 10 
Sales Depa48 48 366 80 06 

www.radwag.com 

Summary of Contents for WLL 1/A1

Page 1: ...m for counting pieces and labelling WLT L series WLL series MANUFACTURER OF ELECTRONIC WEIGHING INSTRUMENTS RADWAG 26 600 Radom Bracka 28 Street POLAND phone 48 48 38 48 800 phone fax 48 48 385 00 10...

Page 2: ...18 7 1 Tarring 19 7 2 Inscribing tare value 20 7 3 Automatic tare 20 7 4 Zeroing 21 8 BALANCE CALIBRATION 22 9 SETTING OF PRINTOUTS CONTENTS FOR GLP PROCEDURES 23 10 TIME AND DATE SETTING 23 11 SETTIN...

Page 3: ...ting pieces with checkweighing 49 19 LABELLING 50 19 1 Quick database search 50 19 1 1 Quick assortment database search 50 19 2 Operator selection and logging in 51 19 3 Article selection 51 19 4 Cont...

Page 4: ...Some basic information 76 26 2 Transmission parameters 76 26 3 Transmission characteristics 77 26 4 Continuous transmission automatic printout 77 26 4 1 Types of printouts 77 26 4 2 Continuous transmi...

Page 5: ...table base Take out all components and assemble them according to below drawings Fig 1 The components installation for the balance with pan size 165 x 165mm For balances 300 x 300mm or 410 x 410mm put...

Page 6: ...turn on the balance 2 INTENDED USE Counting labelling balances are designed for COUNTING PIECES OF THE SAME MASS Connection with label printer enables labels printing Balances are equipped with data b...

Page 7: ...draughts and sudden air movements 9 balance should be placed in room of stable temperature and humidity 9 balance should be placed far from heat sources 9 temperature of the room should be 15 C 30 C...

Page 8: ...rslinged loads hanged under the balance floor In case of using this function remove the hole plug made of plastic placed in the balance floor a suspension can be seen in the hole It is standard equipm...

Page 9: ...f mass 3 upper bargraph in which description of operating mode date and time of internal balance clock are displayed 4 lower bargraph in which part of mass from range of max capacity used currently is...

Page 10: ...ng zeroing Enter to balance menu Enter to counting pieces menu Enter to choice of operating mode Enter to choice of operating mode Change of weighing unit Determining mass of single detail by weighing...

Page 11: ...e of weighing unit Determining mass of single detail by weighing F5 Sending display state to external device PRINT Label printout F6 Balance tarring Balance tarring F7 Operators base choice of operato...

Page 12: ...e of weighing platform ESC Resignation from introduced changes Resignation from introduced changes 5 4 Connecting sockets Fig 4 Sockets 1 Adaptor socket 11V AC 50Hz 2 PC keyboard socket 3 RS 232 socke...

Page 13: ...printout 0 0 off 05 User printout 0 0 off 06 Proj printout 0 0 off 07 Id printout 0 0 off 08 Calibr printout 0 0 off P3 Date Time 01 Date format 0 DA MO YR 02 Time format 0 24 hours 03 Time function 0...

Page 14: ...Prn memory function 02 Prn destination 0 RS 03 Printout no 0 standard 04 Print 1 start 1 05 Print 1 stop 1 06 Print 2 start 1 07 Print 2 stop 1 0 12 Text 1 1 13 Text 2 4 1 92 Tekst 80 0 P7 Units 01 G...

Page 15: ...0 Software number MCB e 08 11 Par printout function 12 Par receive function 13 Password 0 14 Bar code reader function Parameters in user menu can be functional for particular activities e g balance ca...

Page 16: ...to submenu which contents you want to see Press key display will show contents of submenu display II Fig 5 View of balance menu 1 number of main menu 2 choice of function marker 3 name of function 4...

Page 17: ...ition Moving marker downwards Moving marker upwards Confirmation of introduced value Cancellation of changes exit from menu By means of PC keyboard Key Description F2 Enter to balance menu ESC Cancell...

Page 18: ...al changes of external conditions balance should be calibrated according to manual for verified balances function of calibration is not accessible for user Before measurements check if unloaded balanc...

Page 19: ...Tarring display view 1 TARE signature NET is being displayed 2 stable result signature Tarring can be performed repeatedly in the whole balance weighing range Using tare function pay attention not to...

Page 20: ...be 1 05kg as a tare value enter it in the following format 1 050 In the bottom left corner the editing field appears for inscribing a tare value Fig 7b Inscribing tare display view 1 tare designator 2...

Page 21: ...splay shows the net mass of the article Unload the pan Indication returns to zero Put the next package and the cycle repeats 7 4 Zeroing For zeroing display indication press key Indication will return...

Page 22: ...d mass is required it is so called balance calibration In WLT balances it is inaccessible for user The procedure of calibration can be performed only by authorized services of the manufacturer Fig 8 I...

Page 23: ...ce keyboard or with PS 2 keyboard For remaining fields select digits 0 no do not print during report 1 yes print during report 10 TIME AND DATE SETTING Balances have a real time clock which can be mod...

Page 24: ...Format 12 hours Is diffrentiated by placing letters PM or AM on printouts 03 Time With F key enter parameter 03 Time setting according to below scheme Fig 10 Submenu Date Time time setting Set cursor...

Page 25: ...te With F key enter parameter 04 Date setting According to previous description 03 Time set current date After date setting return to weighing mode with changes saving in menu Fig 12 Submenu Date Time...

Page 26: ...conditions are bad vibrations draughts filter should be set as slow or as very slow Effectiveness of filter operating is different for weighing range Filter works slower in time of reaching the final...

Page 27: ...mparison of successive results takes place in declared distance of time e g every 1 s If these result differ in value lower than declared range of AUTOZERO e g 1 interval balance will automatically ze...

Page 28: ...s of weighing from both platforms at the same time 11 8 Automatic tare This function is useful for quick determining net mass of weighed goods when tare values are different for each weighings see cha...

Page 29: ...from 1 to 9999 can be introduced 03 Data bits 1 7 bits 2 8 bits 08 Min mass Give value 04 Stop bits 1 1 bit 2 2 bits 09 Print stab 0 no 1 yes 05 Transmission control 0 none 1 RTS CTS 2 XON XOFF 10 Ga...

Page 30: ...aele Hk 10 Taele S 11 Taele T there are following relations If all of them have attribute 1 yes the balance show only first of them 09 Taele Hk If the measurement is done in units 11 Taele T set the a...

Page 31: ...bled disabled separately 16 OTHER PARAMETERS Users can set parameters influence the operation of the balance in group of the parameters P9 Others e g beep signals etc 01 Address not active 02 ID Setti...

Page 32: ...Contrast changes contrast after entering this function a window appears by means of keys on the balance the contrast on the display can be changed 08 Screen server if the screen server is enabled disp...

Page 33: ...the parameters is very easy and fast procedure of introducing new setting After printing actual parameters to file in the computer user changes the parameters very fast and without any problems User...

Page 34: ...tor After enter to edition of operator a following window will open Fig 19 Screen operators base edition of operator parameters name Name of operator 28 signs index 4 digits Id 6 signs password Passwo...

Page 35: ...of label 2 name of label name Name of label 28 signs index 4 digits Id 6 signs This name must be the same as name of label design saved in printer memory Label design is made in LABELS software attach...

Page 36: ...c label Pcs mass Mass of single piece Tare Tare Gross Gross mass Price price VAT Value Addend Tax Value Value of calculated pcs quantity x price of piece c value Value of calculated pcs on cumulative...

Page 37: ...F Inserting empty line in printout Code buf 1 Bar code read by scanner determined by parameters Start 1 Length 1 Code buf 2 Bar code read by scanner determined by parameters Start 2 Length 2 AI 1 Appl...

Page 38: ...ve the cursor is deleted Method of assigning variables from printout field to fields edited on label sample is as follows Variable from printout window with 01 number will be printed on label in first...

Page 39: ...rice Price VAT Value Addend Tax Value Value of calculated pcs quantity x price of piece C value Value of calculated pcs on cumulative label cc value Value of calculated pcs on cc label EAN13 pcs Intro...

Page 40: ...h 1 Code buf 2 Bar code read by scanner determined by parameters Start 2 Length 2 AI 1 Application identifier 6 characters defined in submenu M1 06 10 AI defining AI 2 As AI 1 AI 3 As AI 1 AI 4 As AI...

Page 41: ...8 characters Index 4 digits Id 7 signs Mass of pc Mass of single piece of particular assortment Min Pcs Minimum quantity of pieces for counting in thresholds result control Max Pcs Maximum quantity of...

Page 42: ...however enter to edition arrow to the right You will see following parameters Name Name of material 28 characters Index 4 digits Id 6 signs Country 16 signs City 28 signs Code Post code 8 characters...

Page 43: ...omatic printout is possible if pieces quantity is bigger than Min Pcs value Result control Activating terminal operating mode with result control label is printed when counted assortment fulfils condi...

Page 44: ...ain ESC key 17 2 2 Printer settings In this menu printer operating is configured Way of moving in menu is analogical to previous ones Fig 27 Screen of printer settings Quantity of labels Quantity of p...

Page 45: ...layed quantity of pieces on the pan 2 total mass of counted detail 3 cumulative labels counter II line of display 4 mass of single detail 5 symbol of stable result 6 symbol of stable zero 7 regular la...

Page 46: ...nce Fig 29 Counting pieces view of display Pressing ENTER will cause moving to Counting pieces mode with automatic setting of single detail mass SMP description on display as current one Notice One sh...

Page 47: ...es on the pan and when result is stable displayed symbol confirm its mass Then balance software automatically calculates mass of single detail and moves to Counting pieces mode indicating on the displ...

Page 48: ...f pieces sufficient it is necessary to save mass of single detail to balance memory 18 2 3 Wprowadzenie masy detalu z bazy danych wagi After introducing assortment from assortment base sample mass SMP...

Page 49: ...y Reference mass will be saved for given assortment under position Pcs mass 18 4 Counting pieces with checkweighing Fig 34 Counting pieces with result control 1 control indicator LO to small quantity...

Page 50: ...much more comfortable and easy 19 1 Quick database search a After entering a database inscribe a record number using PC keyboard b Press arrow c Cursor indicates the ecord you have chosen 19 1 1 Quick...

Page 51: ...ate for given operator confirm with ENTER key Notice By first edition of operators base when base is empty after enter to base press ENTER and introduce given password 1111 After this activity we have...

Page 52: ...n the pan and when result is stable press PRINT key This procedure is repeated when the same assortment is labelled continuously When we want to change the assortment press F8 key enter to assortments...

Page 53: ...s Home key Screen will occur as on drawing 28 Press ENTER key Fig 37 View of screen by cumulative label printing without counters deleting Cumulative label will be printed without n1 counter deleting...

Page 54: ...counters End key With deleting n1 and n2 counters F11 key To print cc label without deleting states of n1 and n2 counters Press End key Press ENTER key cc label will be printed without deleting states...

Page 55: ...ting cc label by n2 counter Balance enables cc label initiating by means of determined state of n2 counter In Operating settings choose cc label position Change value of parameter on COUNTER Move to w...

Page 56: ...inted n1 counter and sums indicator will be zeroed After exceeding total quantity of pieces determined by M2 parameter cc label will be printed n1 and n2 and sums indicator will be zeroed 20 6 Labelli...

Page 57: ...antity of pieces is higher than Min pcs value Parameter is independent from result control If min pcs is set on 0 automatic printout will not take place 21 BARCODES 21 1 General description Barcodes a...

Page 58: ...shops EAN 13 is used together with ISSN International Standard Serial Number for newspapers and magazines 3 digit country code is substituted by 977 21 3 Other barcodes Code 39 Alphanumerical barcode...

Page 59: ...nt 1721 kg or 17 21 g It is important that everybody can decode the information without any additional modifications EAN 128 standard solves this problem It includes a list of Application Identifiers...

Page 60: ...r of Units Contained Used with AI 02 37 Up to 8 characters Dispatch number 401 Up to 30 characters Purchase From Location Code EAN13 or DUNS code 412 Exactly 13 characters Ship To Deliver To Postal Co...

Page 61: ...ets 21 6 Operating with barcode scanners Balance enables cooperation with bar code scanner Scanner is used for fast searching and loading the assortment from assortments base Start 1 Length 1 Paramete...

Page 62: ...rching of assortment will be started draw 33 Caution Signs numbering of read code starts from 1 5 Set parameter Length 1 Choose quantity of signs that are valid by searching draw 33 Value of code dete...

Page 63: ...verlap draw 34 Value of code determined by parameters Start 2 and Length 2 will be saved in Buf Code 2 available as field to print in labels base Fig 43 Value of Buf Code 1 and Buf code 2 9 Leave scan...

Page 64: ...troducing next measurement to balance memory Adding next measurement to series takes place after placing weighed load on the pan result stabilization displayed unit mass and pressing ENTER key User de...

Page 65: ...n series of measurement 7 difference between the heaviest and the lightest detail in given series of measurement 8 value of counted standard deviation 9 value of variation rate 10 measure unit g 11 wo...

Page 66: ...give number of text from which printout should start e g Printout 1 Start 1 and number of text ending given printout e g Printout 1 Stop 40 in such case contents of texts from 1 to text 40 will be pri...

Page 67: ...dard printout can contain no more than 640 signs written in as 80 texts 8 signs each from parameter Text 1 to Text 80 User can design 4 non standard printouts Non standard printouts internal settings...

Page 68: ...ects number of non standard printout which is printed after pressing PRINT button Users can choose Standard result of weighing and declared changes in GLP menu are printed option YES Printout No 1 Pri...

Page 69: ...c unit T Tare mass in basic unit d Date t Hour i Balance no R Software version P Name of project set in GLP menu U User set in GLP menu F Name of current operating mode C Date of last calibration K Ty...

Page 70: ...pieces in EAN13 format for Net value in EAN13 Net value in EAN13 format for supermarkets Date plus declared in operating settings Validity term assigned to assortment Date A plus constant date assigne...

Page 71: ...PSON printers Notice For variables comprising weighing results information from currently chosen platform are printed Special characters used for designing special printouts single sign c CRLF r CR n...

Page 72: ...j R A 29 Text 20 D W A G c D 30 Text 21 a t e d c 31 Text 22 T i m e 32 Text 23 t r n L o 33 Text 24 a d m a s s 34 Text 25 N c 35 Text 26 c S I 36 Text 27 g n a t u r e 37 Text 28 38 Text 29 c F 39 T...

Page 73: ...tering and using keyboard enter the text max 8 signs and confirm with Enter key Repeat the procedure for remaining texts 23 2 2 Choice of non standard printouts If printout as STANDARD is chosen print...

Page 74: ...nce has factory set speed of transmission 9600 bit sec If external device printer computer requires different speed of transmission change in balance menu setting of speed of transmission parameter 24...

Page 75: ...of assortment operators contractors and labels on a computer is much easier than in the balance Procedure 1 While in labelling press F 2 Connect the scale with a computer see 24 1 3 Enter M1 06 Opera...

Page 76: ...some information from the scale or influence the operation of the device E g It is possible to Identify the scale Collect weighing results Keyboard control Display control Changes of variables Other...

Page 77: ...r in factory parameters is not enabled Notice If the parameter DRH is set to 1 this parameter is locked for edition but it is possible to start continuous transmission by using a RS232 command Setting...

Page 78: ...es mass 9 characters justified to the right unit 3 characters justified to the left 26 4 3 Continuous transmission with pauses Continuous transmission with pauses allows users to determine the time in...

Page 79: ...e right unit 3 characters justified to the left This type of printouts can be enabled in parameters Settings RS 232 Aut print when stab Setting the Min mass is possible in Settings RS 232 Min mass Not...

Page 80: ...ames generated after pressing print key results are printed in current units 26 5 Commands and responses syntax 26 5 1 Commands syntax All commands are terminated with CR LF ASCII 13 dec 10 dec Comman...

Page 81: ...error detected or not listed command where ID command 1 4 characters _ space ASCII 32 dec STATUS one character that outlines the response status or a status of the scale Different possibilities A in...

Page 82: ...sult in actaul unit is sent from the balance after stability Function SEND RESULT IN ACTUAL INTERVAL IMMEDIATELY Command SUI CR LF Function ZERO THE BALANCE Command Z CR LF set the balance to zero aft...

Page 83: ...BEEP Command B CR LF sound beep is switched on Function SEND LAST ERROR CODE Command ER CR LF last order of the error is sent Function DISPLAY STRING Command DS CR LF signs are show on the display Fun...

Page 84: ...ing the codes of pressed keys Function TURN ON THE KEYPAD ECHO Command E1 CR LF Function TURN OFF THE SCALE Command O0 CR LF Function TURN ON THE SCALE Command O1 CR LF Function TURN OFF AUTOZERO Comm...

Page 85: ...n mass and calibration mass recorded in the balance memory higher than difference 1 Piece 1 Div 2 10 Singular mass value in counting pieces function less than actual scale interval Piece 10 Div 2 11 M...

Page 86: ...11V AC 50Hz 820mA OIML class Type WLT 3 6 L2 WLT 6 12 L2 WLT 12 30 L2 WLT 30 60 L3 Max capacity 3 6kg 6 12kg 12 30kg 30 60kg Min capacity 1g 5g 10g 25g Readability 0 05 0 1g 0 1 0 2 0 2 0 5 0 5 1 Ver...

Page 87: ...11V AC WLL 6 C1 R WLL 15 C1 R WLL 30 C1 R WLL 30 C2 R WLL 60 C2 R WLL 150 C2 R Type WLL 6 C1 K WLL 15 C1 K WLL 30 C1 K WLL 30 C2 K WLL 60 C2 K WLL 150 C2 K Max capacity 6 kg 15 kg 30 kg 30 kg 60 kg 1...

Page 88: ...necessary program the scanner in appropriate way 1 Programming the type of reading by scanner barcode Symbology Selection SET Enable EAN 13 type of code at choice END 2 Setting the prefix for WLT bala...

Page 89: ...it RS 232C Stop bit 1 bit RS 232C X ON No IEEE 1284 On The way of printing the above printout and setup changes are described in user manual of CITIZEN printer APPENDIX C Setting ZEBRA printers Speed...

Page 90: ...MANUFACTURER OF ELECTRONIC WEIGHING INSTRUMENTS RADWAG 26 600 Radom Bracka 28 Street POLAND Central phone 48 48 38 48 800 phone fax 48 48 385 00 10 Sales Department 48 48 366 80 06 POLAND www radwag c...

Reviews: