RADWAG PUE C32 User Manual Download Page 6

 

 

 

Cleaning  the  weighing  pan  while  still  installed  may  cause 
damage of the measuring system. 

 

 

3.1. Cleaning ABS Components 

 

To  clean  dry  surfaces  and  avoid  smudging,  use  clean  non-colouring  cloths 
made  of  cellulose  or  cotton.  You  can  use  a  solution  of  water  and  detergent 
(soap,  dishwashing  detergent,  glass  cleaner).  Gently  rub  the  cleaned  surface 
and let it dry. Repeat the cleaning process if needed. 

 

In the case of hard to remove contamination, e.g. residues of adhesive, rubber, 
resin,  polyurethane  foam  etc.,  you  can  use  a  special  cleaning  agents  based  
on  a  mixture  of  aliphatic  hydrocarbons  that  do  not  dissolve  plastics.  Before 
using  the  cleanser  for  all  surfaces  we  recommend  carrying  out  tests.  
Do not use cleansers containing abrasive substances. 

 

 

3.2. Cleaning Stainless Steel Components 

 

Avoid  using  cleansers  containing  any  corrosive  chemicals,  e.g.  bleach 
(containing  chlorine).  Do  not  use  cleansers  containing  abrasive  substances. 
Always  remove  the  dirt  using  microfiber  cloth  to  avoid  damage  of  protective 
coating. Daily cleaning routine (removal of small stains): 

1.  Remove the dirt using cloth dipped in warm water. 
2.  For best results, add a little bit of dishwashing detergent. 

 

 

4. MECHANICAL DESIGN 

 

4.1. Dimensions 

 

  

 

 

PUE C32 overall dimensions 

Summary of Contents for PUE C32

Page 1: ......

Page 2: ...2 AUGUST 2020...

Page 3: ...damage immediately unplug the device from the mains Scales to be decommissioned must be decommissioned in accordance with valid legal regulations Do not let battery discharge in case of prolonged stor...

Page 4: ...4 Pictograms 13 7 OPERATING THE MENU 13 7 1 Entering the Menu 13 7 2 Menu Keys 14 7 3 Entering Numbers Text 15 7 3 1 Numerical Box 15 7 3 2 Text Box 16 7 3 3 Diacritical Sign Table 18 7 3 4 Special Si...

Page 5: ...d with the assistance of the manufacturer and the user representatives C RADWAG does not bear any responsibility for damage or losses resulting from unauthorized or inadequate performing of production...

Page 6: ...pecial cleaning agents based on a mixture of aliphatic hydrocarbons that do not dissolve plastics Before using the cleanser for all surfaces we recommend carrying out tests Do not use cleansers contai...

Page 7: ...B connector 4 3 RS232 Connectors RS232 DB9 M connector male front Pin2 RxD Pin3 TxD Pin4 5VDC Pin5 GND RS232 DSUB15 F connector female front Pin8 TxD2 Pin9 5VDC Pin10 GND Pin13 RxD2 4 4 Inputs Outputs...

Page 8: ...Technical Specifications Output parameters Output quantity 4 Output type Solid state relay Cable cross section 0 14 0 5mm 2 Maximum output current 0 5A DC Maximum output voltage 30VDC Input parameters...

Page 9: ...ess to log in Press to cancel the message Press to zero the scale Press to tare the scale Press to change the weighing unit Press to confirm the message Press to confirm the weighing result PRINT Pres...

Page 10: ...nnections 4 or 6 wires shield Load cell excitation voltage 5V DC Maximum signal gain 19 5 mV Display 5 colour graphic display IP rating IP43 Housing ABS plastic Maximum number of connected platforms 1...

Page 11: ...battery status or informs that battery charging is in progress pictogram displayed in a cyclic manner battery charging pictogram displayed continuously battery charged within 75 100 range of permissi...

Page 12: ...re the home screen is to be found in PUE C32 Indicator Software Manual 6 1 Top Bar The top bar displays the following information Working mode name and symbol Device name Wireless communication on Com...

Page 13: ...n customize the screen 6 4 Pictograms The pictograms assigned to operation panel keys are to be found underneath the workspace You can define on screen pictograms individually for each working mode 7...

Page 14: ...n editing numeric and text values Press to select change working mode Press to confirm accept modifications Press to go back Press to discard entering parameter modifications Press to go up the menu P...

Page 15: ...ariable value etc Button functions change depending on the edit box type 7 3 1 Numerical Box Where Digit mode To change keyboard working mode press key Keyboard working mode options upper case charact...

Page 16: ...nter digit 6 Press to enter digit 7 Press to enter digit 8 Press to enter digit 9 Press to enter digit 0 Press to enter sign dot long press Press to delete one character Press to exit the edit box con...

Page 17: ...t Keys Press to enter Press to enter a b c Press to move the cursor to the left long press Press to enter d e f Press to move the cursor up long press Press to enter g h i Press to move the cursor to...

Page 18: ...s characteristic for a particular interface language are automatically added to the table when the given language gets selected Diacritical sign table Polish Diacritical sign table English German Fren...

Page 19: ...press key repeatedly keep pressing the key until you see the home screen press key the home screen is displayed immediately 8 INSTALLER INSTRUCTION The PUE C32 indicator serves as basis of load cell...

Page 20: ...IELD See section 9 3 REF SENSE JP3 not soldered REF SENSE JP4 not soldered IN OUTPUT IN OUTPUT 5V INPUT AGND INPUT 8 2 Connecting 4 Wire Load Cell Connect 4 wire load cell to the main board following...

Page 21: ...ndicator on a post etc DO NOT connect E E Soldering spot on the main board and on the additional A D converter boards 9 FACTORY SETUP To access and modify factory settings and parameters that are made...

Page 22: ...cale type PUE C32 PUE C32 C32 WLX Setting scale type For PUE C32 value only weighing indicator name is displayed metrological data is not Scale name Special name and or name of RADWAG distributor s de...

Page 23: ...02 0 005 0 01 0 02 0 05 0 1 0 2 0 5 1 2 5 10 20 50 Verification units for Range 1 none value unverified version Reading unit Range 2 0 001 0 0000001 50 Reading units for Range 2 Verification unit Rang...

Page 24: ...hreshold parameter Start mass threshold 10 10 90 Start mass value range in Adjustment Weighing instrument adjustment menu External adjustment Scale adjustment refer to section 9 5 1 Start Mass Determi...

Page 25: ...ed where xxx adjustment weight mass Load the weighing pan with a required adjustment weight and press key to confirm Message Adjustment Please wait is displayed Upon adjustment completion message Remo...

Page 26: ...analogous to the linearity correction process for the 1st point Upon declaring requested quantity of linearity correction points press key when Mass edit box is displayed again Section linearity subme...

Page 27: ...from the point of subsequent use The gravity correction value must be entered with reference to tables prepared by Radwag Balances and Scales or calculated using the below formula kal uzy t g g Gcor C...

Page 28: ...28 Scale printer cable ZEBRA Scale printer cable EPSON I O cable Scale Ethernet cable is a standard network cable terminated with RJ45 connectors on both ends...

Page 29: ...29...