6
3. TECHNICAL SPECIFICATIONS
MODEL
MW-01 ver.1
MW-01 ver.2
Communication interface
RS232, RS485,
Ethernet
RS232, PROFIBUS
Power supply
8 ÷ 30VDC
Housing
metal
Ingress protection
IP 66
Operating temperature
-
10°C ÷ 40°C
OIML class
III
Verification units quantity
10 000
Maximum input signal gain
19.5 mV
Minimum voltage per verification unit
0.5 µV
Minimum load cell impedance
80
Ω
Maximum load cell impedance
1200Ω
Load cell excitation voltage
5VDC
Load cell type
4 or 6 wires + shield
Platform quantity
1
2IN/3OUT
Standard
RS232 RS485 baud rate
57600 bit/s by default
3.1. IN/OUT Parameters
The mass converter is equipped with 2 optoisolated inputs, 2 reed switch
outputs and a high speed transistor output (open collector type).
OUT1
– OUT2 Parameters
Output quantity
2
Output type
NO type reed switch
Cable cross-section
0.14 - 0.5 mm
2
Maximum output current
200 mA
Maximum output voltage
50VDC
OUT3 Parameters
Output quantity
1
Output type
Transistor
Umax
5VDC
Imax
100mA