2
INSTALLATION INSTRUCTIONS
Electrical appliance
STANDARDS
The electrical appliance is conform to the standard
EN 60.335-2-43.
The heating appliances are double insulated - Class II and
splash resistant. The appliances also comply with European
directive 2004/108/EC (CE Marking on all appliances).
POSITIONING
• The appliances must be positioned according to the
standards in force in that regard.
• The appliance may be positioned in volume 2 of the bath-
room, insofar as no operating controls (button, switch,
etc.) are in reach of persons in the bath or under the
shower.
• The bottom of the control must be a minimum of 150
mm above floor level.
• The appliance must be positioned a minimum of 50 mm
from the wall and not be located underneath an electric
socket.
WARNING:
For the safety of young children it is advisable to
position the appliance in such a way that the lowest heated
part is a minimum of 600 mm above floor level.
CONNECTION
• The appliance is designed for single-phase 230 V ~ 50 Hz.
• The appliance must be connected to the electrical
network, by means of the original power cable, via a wall
socket (not with a plug and socket!) located behind the
appliance and a minimum of 250 mm above floor level.
•
Neutral
: grey wire -
Phase
: brown wire -
Control wire
(pilot
wire): black wire (if this control/clock-function is present).
Use of the control wire makes it possible to decrease the
temperature if connected to an adapted clock. Open end
means comfort temperature, connected to phase means
reduced temperature. The wire may never be connected
to the earth and must be isolated if this function is not
used.
• If the power cable is damaged it must be replaced with
an appropriate cable. This replacement may only be
carried out by the manufacturer, its after sales service or
equivalent qualified persons, this is to prevent any danger.
• This appliance is filled with a specific amount of heat
conducting fluid (not applicable for the models Likoma
E, Amirante E and Cosmoledo E). If it has to be opened to
carry out repairs then this must only be carried out by the
manufacturer, the manufacturer’ s after sales service
provider, who must be contacted in the event of a leak of
the heat conducting fluid.
• According to the standards in force a separating
omnipolar switch must be provided.
The distance between the contacts will be a minimum of
3 mm.
• If the appliance is installed in a bathroom or shower room
it must be safeguarded with a differential switch with a
maximum of 30 mA.
• When disposing of this appliance, the heat conducting
fluid must be removed by certified subcontractors (not
applicable for the models Likoma E, Amirante E and
Cosmoledo E).
FIXING
“For the correct installation of the appliances it is essential
that the fixing of the appliance is carried out in such a way
that it is suitable for intended use AND predictable misuse.
A number of elements need to be taken into consideration
including the fixing method used to secure the appliance to
the wall, the type and condition of the wall itself, and any
additional potential forces or weights, prior to finalising
installation.”
MISCELLANEOUS
The appliances are not designed for use by persons (and
children) with physical, sensory or mental disabilities or
persons with a lack of experience or knowledge, unless
under the supervision of, or have received the necessary
instructions regarding the use of the appliance, from
a person responsible for their safety. Children should
be supervised to ensure that they do not play with the
appliance.
WARNING
The appliance may only be used for drying laundry
washed in water.
ENG
WASTE DISPOSAL ACCORDING TO THE WEEE DIRECTIVE (2002/96/EC)
The symbol on the product label indicates that the product may not be handled as domestic waste, but must be sorted separately.
When it reaches the end of its useful life, it shall be returned to a collection facility for electrical and electronic products.
By returning the product, you will help to prevent possible negative effects on the environment and health to which the product
can contribute if it is disposed of as ordinary domestic waste. For information about recycling and collection facilities, you should
contact your local authority/municipality or refuse collection service or the business from which you purchased the product.
Applicable to countries where this Directive has been adopted.