24 | P16MI384 - A02 - 01/15
BAYO - THERMOSTAT
ENGLISH
• On the remote control
2. Press buttons “
+
” and “
-
” simultaneously for 5 seconds
(from the
mode) to access the installer mode
3. Press the “
OK
”, button of the transmitter until you
position yourself on segment “
3
”, to display “
rFu
” and
Radio frequency network transmission is fl ashing.
In this menu press “-” to select Uni directional communica-
tion and start radio transmission.
Press “
+
” to select Bi directional communication and start
radio transmission.
IMPORTANT:
“
rFb
” is proposed only to be used when you have a Touch
screen. Not possible to pair one remote control to several
radiators
• On the thermostat
Wait a few seconds and if pairing is successful, LED2 (2c)
will be off (on if radiator is set to have low max surface
temperature) and LED1 (2b) will be either red/green
steady/blinking depending on the mode sent by the digital
display.
More than one radiator may be paired to one remote
control.
• On the remote control:
4. Once all the receivers have been paired, press the
“
OK
”, button of the transmitter until you position
yourself on segment “
9
” to display a “
End
”, then
press “
+
” or “
-
” to return to
mode.
TO ESTABLISH COMMUNICATION BETWEEN THE
THERMOSTAT ALONE AND THE E3 TOUCH SCREEN (PAIRING):
• On the E3 Touch Screen:
1. Go to Installation menu of the E3 Touch screen.
2. Press on “Radio Pairing” then press on “Heating”
3. Choose your Room and confi rm.
4. Then Press “to Radio Pairing.”
• On the thermostat
5. Push the button “fi nger” (2d). For the fi rst 5 seconds,
LED2 (2c) will blink fast orange. This is the signal to
release the fi nger button and only LED2 (2c) will fast
blink which means that the radiator is now in pairing
mode:
Wait a few seconds and if pairing is successful, LED2 (2c) will
be off (on if radiator is set to have low max surface tempera-
ture) and LED1 (2b) will be either red/green steady/blink-
ing depending on the mode sent by the digital display.
Communication between the Touch screen and the
thermostat of the desired radiator is established.
2
d
2
c
2
b
2
a
Press -
P16MI384_RETTI THERMOSTAT MILO - 3 LANG.indd 24
25/01/16 08:30