SF SERIES PRODUCT SPECIFICATIONS 

 

 

The following chart shows fan performance for the SF Series Fan: 

 

Typical CFM Vs Static Pressure "WC 

 

0"  .25"  .5"  .75"  1.0" 1.25" 1.5" 1.75" 2.0" 

SF180 149 137 127 117  96  80  61  40  - 

  

  

 

Power Consumption 

120 VAC, 60Hz 1.0 Amp Maximum 

Maximum Recommended 

Operating Pressure*  (Sea Level Operation)** 

SF180 

 

53 -   71 

watts 

SF180 

 

1.7"  W.C. 

*Reduce by 10% for High Temperature Operation 
**Reduce by 4% per 1000 feet of altitude 

 

 Size 

Weight 

Inlet/Outlet 

SF180 

17.5H”x16W”x6.5D” 

13.1 lbs. 

4.5" OD (4.0" PVC Sched 40 size compatible) 

 
 
 
 
 
Recommended ducting

: 3" or 4"  SF180, , Schedule 20/40 PVC Pipe (Sch.40 prefered)  

Mounting

: Mount on the duct pipe. 

Storage temperature range

: 32 - 100 degrees F. 

Normal operating temperature range: 

-20 - 120 degrees F. 

Maximum inlet air temperature: 

80 degrees F. 

Continuous Duty   
Class F Insulation  
Thermally protected 
3000 RPM 
Rated for Indoor or Outdoor Use 
 
 
 

 

 

 
 

 
 
 

 

Summary of Contents for SF180

Page 1: ...The World s Leading Radon Fan Manufaturer SF180 Installation Instructions RadonAway 3 Saber Way Ward Hill MA 01835 www radonaway com P N IN065 REV C 2 12 ...

Page 2: ...ical Covers Return unit to the factory for service Note An Electrical Switch Box may be installed under the removeable bottom right corner cover 6 All wiring must be performed in accordance with the National Fire Protection Association s NFPA National Electrical Code Standard 70 current edition for all commercial and industrial work and state and local building codes All wiring must be performed b...

Page 3: ... the building occupants The velocity of the outgoing air should be considered in the overall system design In some cases the rushing sound of the outlet air may be disturbing In these instances the use of a RadonAway Exhaust Muffler is recommended 1 4 GROUND WATER In the event that a temporary high water table results in water at or above slab level water may be drawn into the riser pipes thus blo...

Page 4: ...let ducting or where the outlet ducting is likely to produce large amounts of condensation because of high soil moisture or outlet duct material Schedule 20 piping and other thin walled plastic ducting and Aluminum downspout will normally produce much more condensation than Schedule 40 piping which is prefered 1 7 SYSTEM ON INDICATOR A properly designed system should incorporate a System On Indica...

Page 5: ...cation The SF Series Fan is intended be mounted directly on the system piping There is no mounting bracket available for this unit In addition to the inlet and outlet pipe mounts a single vibration mount is provided at the bottom right hand corner of the inner housing underneath the removeable corner cover the vibration mount may be screwed directly to the house siding ...

Page 6: ...ctions See Section 1 8 Fan Wire Connection Green Ground Black AC Hot White AC Common 2 4 VENT MUFFLER optional Install the muffler assembly in the selected location in the outlet ducting Solvent weld all connections The muffler is normally installed at the end of the vent pipe 2 5 OPERATION CHECKS _____ Verify all connections are tight and leak free _____ Insure the SF Series Fan and all ducting i...

Page 7: ...1 watts SF180 1 7 W C Reduce by 10 for High Temperature Operation Reduce by 4 per 1000 feet of altitude Size Weight Inlet Outlet SF180 17 5H x16W x6 5D 13 1 lbs 4 5 OD 4 0 PVC Sched 40 size compatible Recommended ducting 3 or 4 SF180 Schedule 20 40 PVC Pipe Sch 40 prefered Mounting Mount on the duct pipe Storage temperature range 32 100 degrees F Normal operating temperature range 20 120 degrees F...

Page 8: ...donAway 5 YEAR EXTENDED W ARRANTY W ITH PROFESSIONAL INSTALLATION RadonAway will extend the Warranty Term of the fan to 5 years from date of manufacture if the Fan is installed in a professionally designed and professionally installed radon system or installed as a replacement fan in a professionally designed and professionally installed radon system Proof of purchase and or proof of professional ...

Reviews: