Radon TEVISO RA14 Application Notes Download Page 2

 

RA14 Application Notes 

 

 
www.teviso.com           Rev. 12.02.2016           Copyright © Teviso Sensor Technologies Ltd 2015         

 

Suggestions for high voltage supply 

 

Using an electric fence voltage generator is a convenient way to get the required high voltage for 
the collector. Electric fence voltage generators produce pulses between 1000V and 10.000V which 
can be used to charge a capacitor to get the required DC high voltage supply.  
 
A low-cost voltage generator is the Kemo Model M062 (www.kemo-electronic.de). This device 
draws very low current which makes it ideal for battery driven operation. Eight 1.5V alkaline 
batteries size AA can run this generator for approx. 300 hours. In order to achieve 2000V, the 
pulses of 1000V must be doubled with the circuit described below. 

 
 

 

 

  The 1M

 resistor at the output reduces possible electric shocks to a harmless level. 

 

 
Electric fence voltage generators with higher voltage pulses require only one diode and one 
capacitor: 

 

 

 

 
Examples of electric fence voltage generators with voltage pulses higher than 1000V: 
 

 

Kemo Model FG025 (www.kemo-electronic.de) 

 

Patriot Model PE2 (www.patriotchargers.com) 

 

Zareba Model A15   (www.zarebasystems.com) 

 

Suregard Model M2 (http://www.sureguard.com.au/cattle_electric_fence.html) 

 

Summary of Contents for TEVISO RA14

Page 1: ...m the concentration in an adjoining room Because radon concentrations can vary seasonally it would be best to measure radon over the longest period of time possible Ideally this would be one full year because this allows you to determine the annual average radon concentration in your home The average annual radon concentration should not exceed 200 becquerels per cubic meter 200 Bq m in the normal...

Page 2: ...ery low current which makes it ideal for battery driven operation Eight 1 5V alkaline batteries size AA can run this generator for approx 300 hours In order to achieve 2000V the pulses of 1000V must be doubled with the circuit described below The 1MΩ resistor at the output reduces possible electric shocks to a harmless level Electric fence voltage generators with higher voltage pulses require only...

Page 3: ...les the output from the sensor is connected to a PC via microphone input and USB which is used as a DC power source for the sensor After installation of PRA the pulse amplitude and the threshold need to be adjusted a Settings Data Acquisition and Analysis b Set Height threshold to 30 c View Audio Input d Action Start Data Acquisition Position the PB40 Sensor Tester on top of the RA14 Adjust the po...

Page 4: ...on Radon Rn 222 is a colorless odorless and tasteless gas that is radioactive Radon has been considered the second leading cause of lung cancer and leading environmental cause of cancer mortality It can only be detected with special instruments that measure its radioactivity Rn 222 belongs to the radium and uranium 238 decay chain and has a half life of 3 82 days Its four first decay products excl...

Page 5: ...as granite gneiss Radon is a major contributor to the natural radioactivity of the atmosphere near the earth s surface With its half life of 3 82 days it has plenty of time to diffuse through microcracks in rocks and through the soil and to enter the atmosphere Radon concentration varies greatly with season and atmospheric conditions For instance it has been shown to accumulate in the air if there...

Reviews: