VIEW PT STATUS ?
Description
Use this function to identify the number or location of each
point in an area, and to show the current condition of any
point you select. This function is useful as an aid in servicing
the system.
1.
Press the ESC key to enter the Menu. Press NEXT until
the VIEW PT STATUS ? function is displayed.
2.
Press ENT. The display shows AREA X ## (where X =
the area number and ## = the number of points to view).
3.
Press ENT. The display shows PT ## XXXXX (where
XXXXX = the type of point). Press ENT again to see the
current condition of the point. The display will show one
of the following:
• PT###_SHORT_HW which indicates that a hard wire*
(HW) point is shorted.
• PT###_OPEN_HW which indicates that a HW point is
open.
• PT###_NORML_HW which indicates that a HW point is
normal.
• PT###_MISNG_HW which indicates that a HW point is
missing.
4.
Continue to press ENT to see the type and condition of
each point in the area.
5.
Press ESC to return to idle text.
*Hard wire points are connected to the panel by a wire. This is
distinct from systems having points communicating with the
panel by means of radio signals.