![RadioLink RC6GS V2 Instruction Manual Download Page 12](http://html1.mh-extra.com/html/radiolink/rc6gs-v2/rc6gs-v2_instruction-manual_3323549012.webp)
RadioLink Electronic Ltd
8
amount adjustment, and channel 3 servo up side/down side operation amount adjustment during linkage.
Correct the maximum steering angle and left and right steering angles when there is a difference in the
turning radius due to the characteristics, etc. of the vehicle.
Setting item (channel and directio
Steering EPA Throttle EPA
ST:0%~120%(left/ right) TH:0%~120%(forward/brake)
Initial value:100% Initial value : 100%
Aux Servo EPA Aux Servo EPA
CH3:0%~120%(left/ right) CH4:0%~120%(left/ right)
Initial value: 100% Initial value: 100%
Aux Servo EPA Aux Servo EPA
CH5:0%~120%(left/ right) CH6:0%~120%(left/ right)
Initial value: 100% Initial value: 100%
End point adjustment
(1) Access
the function menu (By pressing “Exit” and “Enter” buttons
simultaneously and holding them down for one second),press “Inc(+)”
button twice to chose EAP function.
(2) Press “Enter” button to get into EPA function interface, use “Dec(-)”
or “Inc(+)” button to select the desired setting item , press “Enter” key,
the initial value of your selected setting item will blink, then you can
press “Dec(-)” or “Inc(+)” button to adjust the value of your selected setting item.
(Note: In the interface of adjusting the v
alue, return to the initial value "100%" by pressing “Dec(-)” and “Inc(+)”
buttons simultaneously for about 1 second.)
3. Press “Enter” button, the adjusted value of your selected setting item stops blinking, now the value of your
selected setting item has been set.
4.
Return to the initial screen by pressing “Exit” button twice.
2.5 Steering Exponential "STEXP"
This function is used to change the sensitivity of the steering
servo around the neutral and both ends position. It has no effect
on the maximum servo travel.
Adjust the sensitivity of direction wheel both in neutral position and
ends.
Setup Item
RATE: Steering EXP rate
Adjustment range
-100%~0%~+100%
Initial value: 0%
0%~-100%: Sensitivity around neutral position is low, getting higher when approaching ends.
0%: Sensitivity around the neutral and ends position is equal