batteries). At the same time, in order to make sure the stability of the system, the voltage of the input power 

supply must be within the range of 6.0V to 16.8V (6V to 18 V under the lithium battery mode).

 

 

The protection ways to the battery voltage are different when two types of batteries are used as power supply 

separately. Please check the below table for details: 

   

 

Battery type 

Under-voltage 

protection 

Half-power 

protection 

Over-voltage 

protection 

2S lithium battery 

6.0 V 

6.5 V 

8.7 V 

3S lithium battery 

9.0 V 

9.75 V 

13.05 V 

4S lithium battery 

12.0 V 

13.0 V 

17.4 V 

Non-lithium battery 

6.0 V 

6.5 V 

16.8 V 

 

Note

: In the table, the under-voltage protection value and half-power protection value of the lithium battery are 

based  on  the standard  lithium battery (4.2V is the maximum voltage of a single  cell  of the  standard  lithium 

battery), but the over-voltage protection value is based on the standard high-voltage lithium battery (4.35V is 

the maximum voltage of a single cell of the standard high-voltage lithium battery). 

 

The  introduction  of  the  three  conditions  are  as  follows,  including  under-voltage  protection,  half-power 

protection and over-voltage protection. 

 

 

Under-voltage protection

: It is an under-voltage protection state. When the voltage of the input power 

is lower than this value, the ESC will stop the output control of the motor, which means the ESC will not respond 
to the input signal at this time, and the power light will flash to give a reminder. At the same time, when the 
ESC enters the under-voltage protection state and the battery voltage rises back to the half-power protection 
value, the system will exit the under-voltage protection state. Then the system will return to normal operation, 
and the normal output control of the motor is restored.

 

 

Half-power protection

: It is half-power output protection state. When the voltage of the input power supply 

is lower than the value, the ESC will reduce the output power of the motor to half of the original (The ESC can 

still respond to the input signal at this time). Meanwhile, when the ESC enters the half-power protection state 

and the battery voltage rises to near the over-voltage protection value, the system will not exit the half-power 

protection state. But when the battery voltage drops to the under-voltage protection value, the system will exit 

half-power protection state and enter the under-voltage protection state, with no output control of the motor. 

 

 

Over-voltage protection

: It is over-voltage protection state. When the voltage of the input power is higher 

than this value, the ESC will stop the output control of the motor, which means it will not respond to the input 

signal at this time, and the power light will flash to give a reminder. At the same time, when the ESC enters 

the over-voltage protection state and the battery voltage drops to below the over-voltage protection value, the 

system  will  resume  normal  operation  and  the  normal  output control  of the  motor  will  be  restored. Then  the 

system will return to normal operation, and the normal output control of the motor is restored.

 

2.2 Motor output

 

This  brushed  DC  ESC  only  supports  the  operation  and  output  control  of  brushed  DC  motors,  and  the 

instantaneous peak value of the output current of the ESC can reach 100A. Therefore, when using this ESC, 

Summary of Contents for COOL 9030

Page 1: ...ehicles Drift Cars Crawlers Trailers Bait Boats Rescue Boats Surveying Boats Note This manual only introduces the basic usage of RadioLink COOL 9030 brushed ESC For more information such as tutorials and FAQ please access to RadioLink website www radiolink com or send mail to after_service radiolink com cn ...

Page 2: ... 3 1 1 COOL 9030 Overview 3 1 2 Specifications 4 Part 2 Connection of COOL 9030 5 2 1 Power Input 5 2 2 Motor output 6 2 3 Signal input 7 Part 3 Throttle calibration 8 Part 4 Usage of Jumper Cap 9 Part 5 ESC status 10 5 1 Motor sound 11 5 2 Indicator light 11 5 3 Mixed prompt of motor and light 12 Thanks 12 ...

Page 3: ...nected for a long time without use the battery will eventually be completely discharged which will cause the malfunction of the battery or ESC RadioLink is not responsible for any damage caused by incorrect operation Part 1 Introduction of COOL 9030 1 1 COOL 9030 Overview Power input The power input of the ESC is connected to the power supply At the same time the voltage range of connected power s...

Page 4: ... input power supply and the output voltage of BEC Details will be introduced later LED light description Power light The power light is used to indicate the current self check and power supply status of the ESC system The color of the light is green Details will be introduced later Status light The status light is used to indicate the current self check and operating status of the ESC system The c...

Page 5: ...There is no positive or negative connection between the brushed motor and the ESC If the motor turns incorrectly you can directly change the direction of the motor through the servo phase in the menu of the transmitter or exchange the connection of the two motor output cables of ESC Make sure the right connection and good contact between the motor and the ESC Connection to the battery The battery ...

Page 6: ...rotection state and the battery voltage rises back to the half power protection value the system will exit the under voltage protection state Then the system will return to normal operation and the normal output control of the motor is restored Half power protection It is half power output protection state When the voltage of the input power supply is lower than the value the ESC will reduce the o...

Page 7: ...oncrete cases to prevent the ESC and motor from being damaged or even battery damage accidents 2 3 Signal input The signal input the throttle signal input of this brushed DC ESC can only identify the PWM signal output by a single channel of the receiver The signal with multiple channel codes such as PPM signals S BUS signals etc cannot be recognized At the same time the characteristics of the PWM ...

Page 8: ...ote controller such as servo output ratio and servo midpoint value etc Calibrate the throttle at this time so that the ESC can be adjusted to the signal output of the receiver to achieve the expected effects COOL 9030 is a two way ESC so the throttle calibration method is the same as that of the common two way ESC The specific steps are as follows ESC Calibration Method Preparation Connect the ESC...

Page 9: ... output voltage Jumper cap 1 and 2 are used to set the operation mode of the ESC Jumper cap 3 is for battery type and jumper cap 4 for BEC output voltage The different states of the 4 sets of jumper caps will correspond to the different operation modes of the ESC Choose the operation mode you need determine the type of the battery you use and the requirements for the BEC Then refer to the followin...

Page 10: ...Type When using different types of batteries change the state of Jumper cap 3 to make the battery type match the actual battery Insert Jumper cap 3 when using a lithium battery and remove Jumper cap 3 when using a non lithium battery Wrong state of Jumper cap 3 may cause serious over discharge of the battery and damage the battery Be sure to check Jumper cap 3 to confirm the battery type of the ES...

Page 11: ...check battery type report and operation allowed in sequence as shown in the table below If the sound of the motor is incomplete when the ESC starts inspect the ESC and the equipment connected Motor Sound ESC status Tone beep Do Re Mi Self check finished Short beep Battery type report Long beep Operation allowed Note There are three consecutive tones Do Re Mi in tone beep state of the motor The num...

Page 12: ...ht are as follows Motor sound and red indicator light System state Four consecutive short beeps System high temperature warning Above 85 Flash once every 0 2 second Three consecutive short beeps System low temperature warning Below 40 Flash once every 0 4 second One short beep Throttle signal loss Flash once every 0 6 second Two consecutive short beeps Abnormal throttle signal Flash once every 0 8...

Reviews: