background image

10

11

EN

GL

ISH

Keypad actions and shortcuts

Switch the locator or transmitter on by pressing the 

 key. Once powered up, the keys 

function as follows:

Locator keys

Before you begin

IMPORTANT!  
This guide is intended to be a quick reference guide. We recommend you read the 
full operation manual before you attempt to operate the RD7200 locator.

First use

The RD7200 locators and transmitters can be powered by D-cell alkaline batteries, D-cell 
NiMH batteries, or by an accessory Lithium-Ion (Li-Ion) battery pack.
To fit the D cell batteries in the locator, open the battery compartment and insert two 
D-Cell Alkaline or NiMH batteries, taking care to align the positive (+) and negative (-) 
terminals as indicated.
To fit the D cell batteries in the transmitter, unlatch the accessory tray. The battery 
compartment is located underneath the transmitter body. Use the turnkey to unlatch the 
battery compartment. Insert eight D-Cell Alkaline or NiMH batteries, taking care to align 
the positive (+) and negative (-) terminals as indicated.
Alternatively, you can power the transmitter from a mains or vehicle power source using a 
Radiodetection supplied optional accessory adapter.

Rechargeable battery packs

Lithium-Ion battery packs are available for both locators and transmitters, providing 
superior performance over traditional alkaline batteries. To fit these rechargeable packs, 
follow the instructions provided with each pack.

System setup

It is important that you set up the system according to regional / operational requirements 
and your personal preferences before you conduct your first survey. You can set the 
system up using the menus as described below.

K EY

S H ORT PR E S S

●■■■●

 

  LON G PR E S S

Enter the menu.

Switch power off.

Scroll through locate frequencies  
from low to high.

When using active frequencies:  
Toggles Peak, Peak+, Null, and Guidance 
antenna modes.

Power Mode: 
Scrolls through Power Filters

 for improved 

discrimination of parallel or strong power 
signals.

In Peak+ antenna mode: 
Switch between Guidance and Null arrows.

 

and

 

Increase and decrease gain.  
RD7200 automatically sets gain to  
mid-point when pressed.

Rapidly increase and decrease gain steps 
in 1dB increments.

K EY

S H ORT PR E S S

●■■■●

 

  LON G PR E S S

Enter the menu.

Switch Power off.

Scroll through locate frequencies  
from low to high.

Take voltage and impedance measurements 
using the currently selected frequency.

Take voltage and impedance 
measurements at a standardized frequency.

 

and

 

Adjusts the output signal.

Select standby

 

 

/

 

maximum standard 

power 

.

Transmitter keys

Tip: to scroll through frequencies from high to low, hold 

 while pressing the 

 button 

(applies to both locators and transmitters).

Summary of Contents for RD7200

Page 1: ...RD7200 Utility cable and pipe locator range User Guide Guía del usuario Guide d utilisation Návod k použití 用户指南 Gebruikershandleiding 90 RD7200 UG INT 01 املستخدم دليل ...

Page 2: ...d as a quick reference guide only For detailed instructions including the use of accessories help with eCert please refer to the RD7200 locator Operation Manual and RD Manager Online manuals which are available for download from www radiodetection com The online User Manual library also contains links to the RD Manager Online manuals Certificates of conformity for the RD7200 locators and Tx transm...

Page 3: ...to disassemble the battery packs CAUTION If battery failure is suspected or if the battery shows any sign of discoloration physical damage return the entire unit to an authorized repair center for investigation and repair Local national or IATA transport regulations may restrict the shipment of faulty batteries Check with your courier for restrictions and best practice guidelines Your local Radiod...

Page 4: ...ocator screen icons 16 Signal strength bargraph with peak marker 17 Signal strength readout 18 Null Proportional Guidance arrows 19 Battery level 20 Sensitivity readout 21 Volume level 22 Radio Mode icon 23 Power Mode icon 24 Accessory Measurement icon 25 A Frame icon 26 Frequency current menu readout 27 Antenna modes icon Indicates antenna mode selection Peak Peak Null Guidance 28 Sonde icon Indi...

Page 5: ...ows 9 Measure key Transmitter screen icons 10 Battery level indicator 11 Operation mode readout 12 Standby icon 13 Output level indicator 14 Clamp icon Indicates when a signal clamp or other accessory is connected 15 DC Power connected indicator 16 Induction mode indicator 17 A Frame Indicates when the transmitter is in Fault Find Mode 18 Voltage warning indicator Indicates that the transmitter is...

Page 6: ...re available for both locators and transmitters providing superior performance over traditional alkaline batteries To fit these rechargeable packs follow the instructions provided with each pack System setup It is important that you set up the system according to regional operational requirements and your personal preferences before you conduct your first survey You can set the system up using the...

Page 7: ...t High or Low sound levels SWING Enable or disable Swing warning INFO Shows the software version run a Self Test display the date of the most recent service recalibration M CAL or the most recent eCert calibration Transmitter menu options VOL Adjust the speaker volume from 0 mute to 3 loudest FREQ Enable or disable individual frequencies BOOST Boost transmitter output for a specified period of tim...

Page 8: ... is better to use a low frequency on larger low impedance utilities and move to a higher frequency on smaller high impedance utilities The lowest power setting required to trace the target utility should always be used to minimize the risk of false trails The transmitter can apply a signal using three different methods Direct connection In direct connection you connect the transmitter directly to ...

Page 9: ...able or pipe being located or when the locator determines that signal conditions are too poor for reliable measurements Using accessories The locator and transmitter are compatible with a wide range of accessories For detailed information on using any of the accessories below please refer to the RD7200 locator operation manual Transmitter signal clamps When it is not possible to connect directly o...

Page 10: ...nals and connection sockets are clean free of debris and corrosion and are undamaged Do not use this equipment when damaged or faulty Batteries and power supply Only use the rechargeable battery packs chargers and power supplies approved by Radiodetection If not using rechargeable packs use good quality Alkaline or NiMH batteries only Batteries should be disposed of in accordance with your company...

Page 11: ...he or arrows 5 Press the key to select YES 6 Press the key to begin the Self Test 7 Once the Self Test is completed the result PASS or FAIL will be displayed 8 Restart the locator using the key RD Manager Online PC Software RD Manager Online is the RD7200 locator system PC companion and it allows you to manage and customize your locator RD Manager Online is also used to retrieve and analyze survey...

Page 12: ...n Germany Groendahlscher Weg 118 46446 Emmerich am Rhein Germany Tel 49 0 28 51 92 37 20 rd sales de spx com Radiodetection Asia Pacific Room 708 CC Wu Building 302 308 Hennessy Road Wan Chai Hong Kong SAR China Tel 852 2110 8160 rd sales asiapacific spx com Radiodetection China 13 Fuqianyi Street Minghao Building D304 Tianzhu Town Shunyi District Beijing 101312 China Tel 86 0 10 8146 3372 rd serv...