Page
5
of
60
©
2019 Radiocrafts AS
MBUS User Manual (ver 2.01)
MBUS USER MANUAL
1.2 Differencies between RC11xx and RC17xx series
This User Manual describes the embedded protocol of the Wireless M-Bus modules from Radiocrafts. The MBUS
firmware is available as different feature sets targeting specific applications. The hardware has the same size and
pin-out for all frequency versions, and the different feature sets available are listed in the table below. The feature
sets and the embedded functions are independent of the frequency, so this User Manual is valid for all versions
RC11xx(HP)-MBUS3 and RC1701HP-MBUS4. Detailed information on how to use the different feature sets is
found in this User Manual. Additional information about the Wireless M-Bus packet structure for NTA 8130
compliance is described in Application Note 011 and is available on request.
Table 1
– MBUS Feature Sets Overview
Feature List
Feature Set
RC11xx-MBUS
(MBUS3
TM
)
RC17xx-MBUS
(MBUS4
TM
)
General
General Wireless M-Bus modem,
with OMS featureset.
Wireless M-Bus mode N at 169
MHz
Network role
Master, Slave or Repeater
Master, Slave or Repeater
Modes
C1, S1, S2, T1, T2
N1, N2
Encryption
AES mode 4 and 5, and ELL
encryption mode 1
AES mode 4 and 5, and ELL
encryption mode 1
Installation mode
Yes, according to OMS
Yes
Number of installed meters
Up to 64
256 internally, unlimited externally
(>1000 meters per concentrator)
Filter function
Master only receives messages
from installed/registered meters
(optional)
Master only receives messages
from installed/registered meters
(optional)
Two way communication
Yes, according to OMS
Yes, for N2 mode
Automatic message generation
from Master
Yes, patented automatic message
generation.
According to OMS.
Supporting two-way slaves.
Standard response or a
predefined message from
mailboxes or templates.
Yes, patented auto message
generation.
Special support for handling of
> 1000 meters (Slaves).
The command set used to configure the MBUS modules are described in Appendix A .
1.3 Optional custom specific version
As an option to the standard feature sets, a full Wireless M-Bus application layer can be integrated in the module
based on customer specification. In this case all the application layer protocol and timing will be handled internally
by the module. Radiocrafts offer multiple such variants:
•
MBUS with Pulse Counter
o
RC1140/60/70/80-MPC1
o
RC1701HP-MPC1
•
MBUS Sensor Module
o
RC1180-MSM
o
RC1701HP-MSM
•
Wize protocol
o
RC1701HP-WIZE