background image

the channel and press DELAY until DELAY appears on the display.  When the
scanner stops on the channel, it waits for 2 seconds after each
transmission before it resumes scanning.

To program a 2-second delay for any active frequency while searching, press
DELAY until DELAY appears on the display.  When the scanner stops on a
frequency, it waits for 2 seconds after each transmission before it resumes
searching.

To turn off the programmed delay on any active channel, press DELAY while
the channel is still active.  DELAY disappears from the display.

LOCKING OUT A CHANNEL

You can scan channels faster by locking out those that have a continuous
transmission, such as a weather channel.

To lock out a channel while scanning, press L/OUT when the scanner stops on
the channel.  To lock out a channel manually, manually select the channel
and press L/OUT until L/OUT appears on the display.

To remove the lockout from a channel, manually select the channel and press
L/OUT so L/OUT disappears from the display.

NOTES:  You can still manually select locked-out channels.

        You cannot lock out all channels.  There must be at least one
        active channel in a bank.

PRIORITY

The priority feature lets you scan through the programmed channels and
still not miss an important or interesting call on a specific channel.  To
program a stored channel as the priority channel, press PGM, the desired
channel number, and then PRI.

NOTE:  You can only select one channel as the priority channel.

To turn on the priority feature, press PRI during scanning.  PRI appears on
the display.  The scanner checks the priority channel every 2 seconds, and
stays on the channel if there is activity.  P appears to the left of the
display whenever the scanner is set to the priority channel.

Summary of Contents for PRO-2039

Page 1: ......

Page 2: ...ough all non locked channels in the active banks see Locking Out Channels NOTE An improper SQUELCH setting might keep the scanner from scanning see Turning on the Scanner Setting Volume and Squelch TURNING CHANNEL STORAGE BANKS ON AND OFF When you first turn on the scanner the scanner scans all ten channel storage banks As the scanner scans a bank the bar under the bank s number flashes To turn of...

Page 3: ...umber you want to program 2 Press PGM PGM appears on the display 3 Using the number keys enter the frequency you want to store in that channel 4 Press ENTER to store the frequency If you make a mistake in Step 3 ERROR appears on the display Press CLEAR and repeat Steps 3 and 4 5 Repeat Steps 1 4 to program more channels or Steps 2 4 if you want to program the next channel in sequence SEARCHING FOR...

Page 4: ...per limit or press DOWN arrow to search from the upper to the lower limit L SRCH and UP or DOWN arrows appear on the display 7 When the scanner stops on a transmission press MON to store the frequency in the current monitor memory or press UP or DOWN arrow to continue the search Direct Search When the scanner is stopped on a frequency you can search up or down from the current displayed frequency ...

Page 5: ...ner stores the frequency into the channel MANUALLY SELECTING A CHANNEL You can continuously monitor a specific channel without scanning This is useful if you hear an emergency broadcast on a channel and do not want to miss any details even though there might be periods of silence or if you want to monitor a locked out channel To select a channel just press MAN Enter the channel number and press MA...

Page 6: ...l To lock out a channel manually manually select the channel and press L OUT until L OUT appears on the display To remove the lockout from a channel manually select the channel and press L OUT so L OUT disappears from the display NOTES You can still manually select locked out channels You cannot lock out all channels There must be at least one active channel in a bank PRIORITY The priority feature...

Page 7: ...I during scanning until PRI disappears from the display SPEED Press SPEED while scanning searching to alternate between low and high speeds You can scan at either 8 or 25 channels per second and search at either 8 or 50 frequencies per second ...

Page 8: ...microV Spurious Rejection at 154 MHz FM 50 dB Selectivity 10 kHz 6 dB 20 kHz 50 dB IF Interference Ratio 10 7 MHz at 154 MHz 50dB Scanning Rate Fast 25 channels sec Slow 8 channels sec Search Rate Fast 50 steps sec Slow 8 steps sec Priority Sampling 2 seconds Delay Time 2 seconds IF Frequencies 10 7 MHz and 455 kHz Squelch Sensitivity Threshold Less than 1 0 microV Tight FM S N N 25 dB Tight AM S ...

Page 9: ...equencies correctly frequencies Programmed frequencies Avoid programming frequencies that are the same as listed under Birdie Frequencies Birdie frequencies or only listen to them manually ERROR appears on the Programming error Reprogram the frequencies correctly display frequencies correctly Keys do not work or Undetermined error Reset the scanner display changes at see Resetting Initializing the...

Reviews: