Figure 35: System – General Screen Shot
UNIT ID is where you can change the identification number of the DVR. This is
used in conjunction with the Security Function as shown in Figure 42 on Page 51.
VIDEO TYPE can be changed to either NTSC or PAL.
RECORD FILE SIZE is selectable to 15 or 30 minutes.
HDD OVERWRITE, when set to YES allows the DVR to overwrite the hard
drive, First In, First Out, as the DVR needs more room for storage. When this is
set to NO, the DVR will write once and then stop, lighting the HDD FULL LED
on the face of the DVR. When this setting is set to NO, the user must manually
delete files off the hard drive, or format the drive to get the DVR to record more.
RECORD MODE can be set to IGNITION, TIMERS, IGN or TIMER, and IGN
and TIMER. The record timers are set in the SCHEDULE section as shown in
Figure 69 on Page 68.