T

EST 

M

ESSAGES

 

 

The sensor can be triggered to send test messages by placing a magnet next to the side of the 
sensor. The location of the magnet is indicated by the triangular notch on the side of RBSx01 
and RBSx05 sensors. RBSx04 sensors do not have this capability. There is a small magnetic Hall 
effect sensor that will detect the presence of a magnet and send a message. This can be used for 
diagnostic purposes to ensure the sensor is within range and connected to the network. 

 

6.

 

M

ESSAGE 

P

ROTOCOL

 

 

This section defines the protocol and message definitions for the sensor.  

 

If the standard Radio Bridge console (console.radiobridge.com) is not used, refer to this section 
to decode the sensor data and configure the sensor through downlink messages. 

Radio Bridge provides a web-based console at console.radiobridge.com 
to configure and monitor sensors. Usage of this console is highly 
recommended for most customers rather than implementing the 
protocols defined in this section. 

 

 

 

6.1.

 

Common Messages 

 

There are common messages across all wireless sensors that are defined in the document 

“Common Sensor Messages” which is available on the Radio Bridge website. 

 

 

Common messages include basic error messages, tamper, supervisory, and downlink ack. It is 
important to refer to that document prior to decoding the messages defined in this section. 

Refer to the document “Common Sensor Messages” for definitions of all 

common messages. Common messages are not defined in this document.

 

 

 

 

Summary of Contents for RBS306-TILT-HP-US

Page 1: ...Wireless High Precision Tilt Sensor User Guide VERSION 1 3 SEPTEMBER 2019...

Page 2: ...SSAGE PROTOCOL 6 6 1 Common Messages 6 6 2 Uplink Messages 7 6 2 1 Temperature Compensation 8 6 3 Downlink Messages 9 6 3 1 Periodic Reports 9 6 3 2 Hold Time 10 6 3 3 Threshold Mode 10 6 3 4 Report O...

Page 3: ...orientation When the sensor is tilted either away from or toward the vertical orientation by a specified amount an alert is sent to the wireless network The high precision tilt sensor has precision to...

Page 4: ...ay 2019 Modified precision on measurement 1 2 May 2019 Added temperature for compensation 1 3 September 2019 Updated common sections 2 3 Document Conventions Table 2 Document Conventions Font Icon Mea...

Page 5: ...O BRIDGE INC WIRELESS HIGH PRECISION TILT SENSOR PAGE 4 OF 15 3 TECHNICAL SPECIFICATIONS 3 1 Absolute Maximum Ratings Table 4 Absolute Maximum Ratings Parameter Rating Units Operating ambient temperat...

Page 6: ...ly high voltage for the life of the battery and then experience a rapid drop near the end whereas an alkaline battery will experience a more gradual reduction in voltage over time Radio Bridge sensors...

Page 7: ...If the standard Radio Bridge console console radiobridge com is not used refer to this section to decode the sensor data and configure the sensor through downlink messages Radio Bridge provides a web...

Page 8: ...age is the whole integer component and byte 2 is in tenths of a degree For example a measurement of 48 7 degrees would be represented as 0x30 and 0x07 respectively The tilt events are defined in the f...

Page 9: ...x03 of the uplink message is a two s compliment signed integer value representing the ambient temperature inside the sensor in degrees C This is reported because MEMS based accelerometers are sensitiv...

Page 10: ...a setting of 0x01 selects Report on Change mode This selection defines bytes 3 6 as shown in the sections below 6 3 1 Periodic Reports The tilt sensor can also send periodic updates and this is define...

Page 11: ...a range of 250 milliseconds 1 minute If the hold time is 0 the feature is disabled and an alert will be sent any time the orientation changes 6 3 3 Threshold Mode The angles in bytes 3 6 define the a...

Page 12: ...gle of 16 8 degrees the values would be 0x10 and 0x08 respectively 6 3 4 Report On Change Mode The report on change feature will create an alert when the angle of the tilt increases or decreases by a...

Page 13: ...Angle for report on change mode toward the 0 degree vertical position fractional value Since the high precision tilt sensor has precision to 0 1 degrees the angles are defined by both an integer valu...

Page 14: ...DGE INC WIRELESS HIGH PRECISION TILT SENSOR PAGE 13 OF 15 7 MECHANICAL DRAWINGS The mechanical drawings provided in this section are for the main body of the sensor All dimensions are inches unless ot...

Page 15: ...sensors FCC ID 2APNUSFM10R2 LoRaWAN RBS301 RBS304 and RBS305 sensors FCC ID 2APNUCMABZ LoRaWAN RBS306 sensors This device contains FCC IAU792U13A16858 This device contains equipment certified under I...

Page 16: ...adio Bridge provides this document as is without warranty of any kind expressed or implied including but not limited to the implied warranties of fitness or merchantability for a particular purpose Ra...

Reviews: