R
ADIO
B
RIDGE
RBM101
I
U
SER
G
UIDE
C
OPYRIGHT
©
2017,
R
ADIO
B
RIDGE
I
NC
.
R
ADIO
B
RIDGE
RBM101
I
U
SER
G
UIDE
P
AGE
12
OF
19
3.3.1.12
DF
–
Duplicate Filter
Sets the window of time to filter duplicate packets. If an identical packet arrives within the
window defined by this parameter, it is discarded and not reported to the host. The parameter
is a 16-bit value in units of 10ms.
Default:
01F5 (5 seconds)
This does not block new events from the same sensor that fall within this window. Each new
event should contain an updated message count which makes the new event unique. If a
sensor is not updating the message count or if this feature should be disabled for any other
reason, a setting of 0000 will disable the feature completely.
Note that most sensors send the same message up to 8 times and thus will need to be filtered
at the host if this feature is disabled.