R
ADIO
B
RIDGE
RBM101
U
SER
G
UIDE
C
OPYRIGHT
©
2017,
R
ADIO
B
RIDGE
I
NC
.
R
ADIO
B
RIDGE
RBM101
U
SER
G
UIDE
P
AGE
22
OF
35
0001
Bad packet
Received a packet over the radio that cannot be
understood or interpreted properly. May indicate a
device is not compliant with the SubGig standard
0002
Out of sequence
Received a packet over the radio that was out of
sequence. See the SubGig spec for more detail. The
counters are reset at power on and are not saved in non-
volatile memory.
0003
Not Ready for new
commands
The host is attempting to send new commands but the
device is not ready to receive new commands yet.
0004
Incorrect command
format
The format of the serial command sent to the device is
wrong.
0005
Command invalid
for coordinators
A command was sent to a coordinator that is invalid for
coordinators.
0006
Command invalid
for endpoints
A command was sent to an endpoint that is invalid for
endpoints
0007
Add endpoint failed The host attempted to add an endpoint but the process
failed. Likely due to maximum endpoints exceeded.
0008
Remove endpoint
failed
The host attempted to remove an endpoint but the
process failed. Likely due to endpoint not in the list.
0009
Not ASCII coded
hex
The values provided were not ASCII coded hex values.
000a
Command not
recognized
A command was sent to the device that was not
recognized
000b
Key received, no
provisioning
An endpoint received a key that was broadcast from a
coordinator but no provisioning key has been set yet. Key
is rejected.
000c
Discover endpoints
timeout
The discover endpoint process for a coordinator timed
out with no endpoints found.
000d
Unencrypted
packet
Received an unencrypted packet while encryption was
enabled.
000e
Supervisory not
received
Message from a coordinator indicating that a supervisory
message was not received from an endpoint.