background image

Summary of Contents for VK Link

Page 1: ......

Page 2: ...kage Contents 9 4 2 VK Link 10 4 3 Control Panel 12 5 Installation 14 5 1 Installation Notes 15 5 2 Wiring 18 6 Operation 19 7 Maintenance 22 7 1 Cleaning the Pre Filter 23 7 2 Replacing the Carbon and HEPA Filters 24 7 3 Replacing the Reactor Chamber 26 7 4 Troubleshooting 29 8 Specifications 30 8 1 Performance Data 32 8 2 Dimensions 34 9 Support 36 ...

Page 3: ...1 VK Link Product Manual V1 0 Radic8 VK Link 1_en Copyright 2021 Radic8 Page 1 of 36 ...

Page 4: ... to us This product manual contains information that is vital to the safe operation and maintenance of the VK Link This manual also contains the performance data required to design appropriate efficient airflow systems This device should only be used for its intended purpose Radic8 VK Link 1_en Copyright 2021 Radic8 Page 2 of 36 ...

Page 5: ...isconnect from power Contact your local distributor for support Do not operate the unit with a damaged power cord or plug Do not attempt to alter or modify the power cord or plug To avoid the risk of electric shock this equipment must only be connected to supply mains equipped with a protective earth Wear personal protective equipment PPE such as a disposable face mask and gloves when handling ser...

Page 6: ...ilizing PCO photocatalytic oxidation technology Labelling Symbols Follow instructions for use Caution Manufacturer identification Date of manufacture Catalog number Serial number UV light warning Maximum and minimum temperature limits in which the item shall be stored transported or used Waste electrical and electronic equipment WEEE It is the responsibility of the end user to dispose of this equi...

Page 7: ...is required for products manufactured anywhere in the world that are marketed in the EU Federal Communications Commission mark This is a voluntary mark employed on electronic products manufactured or sold in the United States indicating that the electromagnetic radiation from the device is below the limits specified by the Federal Communications Commission and the manufacturer has followed the req...

Page 8: ...terference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver C...

Page 9: ...d manufacturer s warranty of 12 months This warranty may be extended by prior agreement with authorized distribution partners Please refer to your local distributor for queries related to warranty or claims Radic8 VK Link 1_en Copyright 2021 Radic8 Page 7 of 36 ...

Page 10: ...ion possibilities include Fresh air delivery Filter outdoor air and neutralize gases and VOCs before delivering the air indoors Recirculation Circulate filtered and decontaminated indoor air within or between rooms Integration Add air purification and decontamination to existing ventilation or HVAC systems Positive negative pressure applications Create air pressure differentials and transfer syste...

Page 11: ...ts VK Link 200mm inline fan Control panel Remote control batteries not included 2 x C13 power cables 4 x Wall mount brackets Product brief 4 x Ceiling mount brackets Radic8 VK Link 1_en Copyright 2021 Radic8 Page 9 of 36 ...

Page 12: ...4 2 VK Link Pre filter Carbon filter HEPA filter Reactor Chamber Wall mount brackets Ceiling mount brackets 200mm PVC reducers Radic8 VK Link 1_en Copyright 2021 Radic8 Page 10 of 36 ...

Page 13: ...AC input via control panel Front panel Hand screws Radic8 VK Link 1_en Copyright 2021 Radic8 Page 11 of 36 ...

Page 14: ...4 3 Control Panel Power button UV C button Fan button Mode button UV C indicator Radic8 VK Link 1_en Copyright 2021 Radic8 Page 12 of 36 ...

Page 15: ...acement indicator CO2 indicator Infrared receiver CO2 sensor Display panel AC input via mains supply Fan output to 200mm inline fan UV C output to VK Link Radic8 VK Link 1_en Copyright 2021 Radic8 Page 13 of 36 ...

Page 16: ...es airflow dynamics access and safety considerations Please refer to the performance data for both the VK Link and the supplied 200mm inline fan at the end of this Product Manual when designing appropriate applications for the VK Link The VK Link may only be installed by a qualified HVAC designer or specialist The VK Link is not intended to be installed by end users Radic8 VK Link 1_en Copyright 2...

Page 17: ...ection Fan Direction Ensure the 200mm inline fan drives air in the direction of the airflow The VK Link must not be installed outdoors or anywhere else it may be exposed to the elements When integrating the VK Link with conditioning systems ensure the VK Link is installed upstream of before any cooling or heating coils Radic8 VK Link 1_en Copyright 2021 Radic8 Page 15 of 36 ...

Page 18: ...or optimum performance install the fan downstream of after the VK Link Fan Distance Ensure the 200mm inline fan is installed as close to the VK Link as possible Radic8 VK Link 1_en Copyright 2021 Radic8 Page 16 of 36 ...

Page 19: ...Radic8 VK Link 1_en Copyright 2021 Radic8 Page 17 of 36 ...

Page 20: ...rol panel via the mated 4 pin communication and power cable Connect the VK Link to the control panel using a C13 IEC power cable Connect the control panel to the mains AC supply using a C13 IEC power cable Before installation or use ensure the correct mains AC voltage Radic8 VK Link 1_en Copyright 2021 Radic8 Page 18 of 36 ...

Page 21: ...inline fan When the device is turned on the display panel will illuminate Switching the Reactor Chamber on or off The VK Link s Reactor Chamber can be switched on or off independently by pressing the UV C button When the Reactor Chamber is on the UV C indicator is illuminated When the Reactor chamber is off the UV C indicator is dark In this mode the inline fan continues to drive air through the p...

Page 22: ...m are detected and the CO2 indicator will illuminate When CO2 levels drop below 800ppm the CO2 indicator will go dark and the fan speed will decrease Display modes Press the mode button to cycle between the display modes Each mode shows different information on the display panel Display mode Description Fan speed The selected fan speed either AUTO FAN 1 FAN 2 or FAN 3 Time The current time 24 hour...

Page 23: ...panel and the last digit will flash 3 Press the fan button to increase a flashing digit and the UV C button to decrease a flashing digit 4 To move between digits press the mode button 5 Repeat until the correct time is set 6 Press and hold the mode button for 3 seconds to exit time adjustment mode Radic8 VK Link 1_en Copyright 2021 Radic8 Page 21 of 36 ...

Page 24: ...e covers replaced wipe any excess sanitizer off the chassis and ensure it is completely dry before switching the device back on To access the filters or Reactor Chamber undo the 4 hand screws and remove the front panel Always wear personal protective equipment PPE such as a disposable face mask and gloves when opening a VK Link or handling a VK Link that has previously been installed Maintenance s...

Page 25: ...ptimal airflow 1 Slide out the pre filter 2 Clean the pre filter by wiping it with a dust or microfiber cloth 3 If required the pre filter can be cleaned using warm water However ensure the pre filter is completely dry before reinstallation 4 Reinsert the pre filter Radic8 VK Link 1_en Copyright 2021 Radic8 Page 23 of 36 ...

Page 26: ... HEPA filters are not reusable and should be replaced every 6 months Carbon filter 1 Slide out the used carbon filter 2 Safely dispose of the used carbon filter see below 3 Slide in a new carbon filter Radic8 VK Link 1_en Copyright 2021 Radic8 Page 24 of 36 ...

Page 27: ...mmend lightly misting the used filter material with an alcohol based sanitizer Used filters should be placed in a large plastic bag tied or sealed and disposed of Filters bordered by an aluminum frame can be disassembled before disposal In this case the aluminum frame can be disposed of or recycled separately to the filter material itself Radic8 VK Link 1_en Copyright 2021 Radic8 Page 25 of 36 ...

Page 28: ...en this time has elapsed 1 Disconnect the Reactor Chamber power connector 2 Remove the 2 screws holding the Reactor Chamber brackets and earth wires to the VK Link chassis If the VK Link is integrated into a larger HVAC system ensure the entire HVAC system is switched off before replacing the Reactor Chamber Radic8 VK Link 1_en Copyright 2021 Radic8 Page 26 of 36 ...

Page 29: ...3 Slide out the brackets and Reactor Chamber from the body of the unit 4 Remove the 4 screws from each bracket and remove the brackets Radic8 VK Link 1_en Copyright 2021 Radic8 Page 27 of 36 ...

Page 30: ...ol panel for 10 seconds to reset the Reactor Chamber runtime to zero This will also turn off the control panel UV C replacement indicator Safe disposal of the Reactor Chamber The UV C Reactor Chamber consists of plastic steel electrical components UV lamps containing a small amount of mercury and hexagonal tube filters coated in a thin layer of titanium dioxide As such expired Reactor Chambers sho...

Page 31: ...ature of the internal PCB has exceeded 80 C Switch the unit off The fan motor is not functioning correctly Switch the unit off Please contact your local distributor if any of the above errors are displayed Radic8 VK Link 1_en Copyright 2021 Radic8 Page 29 of 36 ...

Page 32: ...ctrical input 110 120V AC 50 60Hz 220 240V AC 50 60Hz Maximum power 110 120V AC 210W Maximum power 220 240V AC 180W Maximum current 110 120V AC 1 95A Maximum current 220 240V AC 0 85A Warranty 12 months Protection rating IP20 Based on two air changes per hour and a ceiling height of 2 4m Dependent on operating environment Ensure you are using the correct voltage for your region Radic8 reserves the...

Page 33: ...Operation and transport conditions Temperature 10 45 C Relative humidity non condensing 30 80 Pressure 80 106kPa Radic8 VK Link 1_en Copyright 2021 Radic8 Page 31 of 36 ...

Page 34: ...nsions mm 350 220 Dimensions in 13 8 x 8 7 Reducer 200mm Noise 52 58 dB Airflow 336 500 CFM Electrical input 110 120V AC 50 60Hz 220 240V AC 50 60Hz Maximum power 220 240V 131W Maximum power 110 120V 160W Maximum current 220 240V 0 590A Maximum current 110 120V 1 450A Speed 1650 2450 rpm Air pressure 167 370 Pa Ensure you are using the correct voltage for your region Radic8 VK Link 1_en Copyright ...

Page 35: ...200mm inline fan curves Radic8 VK Link 1_en Copyright 2021 Radic8 Page 33 of 36 ...

Page 36: ...8 2 Dimensions All dimensions are specified in millimeters VK Link 200mm inline fan Radic8 VK Link 1_en Copyright 2021 Radic8 Page 34 of 36 ...

Page 37: ...Control panel Radic8 VK Link 1_en Copyright 2021 Radic8 Page 35 of 36 ...

Page 38: ...tact your local VK Link distributor Radic8 PTE Ltd 7 Temasek Boulevard 12 07 Suntec Tower One Singapore 038987 info radic8 com You can find the model and serial number on the back of your device Radic8 VK Link 1_en Copyright 2021 Radic8 Page 36 of 36 ...

Reviews: