SFK 34 - RAD - ING - Manuale - 1807.1_V3_firm.L225A
2 Ta
b
e
lla
pa
ra
m
e
tr
i_
M
IA
H
4
0
4
_
fir
m
.L
22
5A
_
S
F
K
_
E
N
2. FIRST START-UP
SUPPOR
T
C
ENTRE
PARAMETER
DESCRIPTION
RANGE
FUNCTION
P06
FAN MINIMUM SPEED ADJUSTMENT
THROUGH THIS PARAMETER YOU
CAN SET THE FAN MINIMUM SPEED
CORRESPONDING TO THE MINIMUM
POWER OF THE BURNER.
THE VALUE IS PRE-SET BASED ON THE SET
POWER (SEE PARAMETER P00) AND ON
THE GAS TYPE (SEE PARAMETER P01).
43 - 255
VALUE EXPRESSED IN HERTZ (1HZ = 30 RPM)
P07
FAN MAXIMUM SPEED ADJUSTMENT
THROUGH THIS PARAMETER YOU
CAN SET THE MAXIMUM FAN SPEED
CORRESPONDING TO THE MAXIMUM
POWER OF THE BURNER.
THE VALUE IS PRE-SET BASED ON THE SET
POWER (SEE PARAMETER P00) AND ON
THE GAS TYPE (SEE PARAMETER P01).
43 - 255
VALUE EXPRESSED IN HERTZ (1HZ = 30 RPM)
P08
STARTING STEP ADJUSTMENT
THROUGH THIS PARAMETER YOU CAN SET
THE FAN SPEED DURING THE START-UP.
THE VALUE IS PRE-SET BASED ON THE SET
POWER (SEE PARAMETER P00) AND ON
THE GAS TYPE (SEE PARAMETER P01).
43 - 255
VALUE EXPRESSED IN HERTZ (1HZ = 30 RPM)
P09
D.H.W RUN-DOWN
THROUGH THIS PARAMETER YOU CAN SET
THE TIME NECESSARY FOR THE WATER
HEATER TO REACH THE MINIMUM SET
POWER, AFTER THE BURNER START-UP.
02
-
15
VALUE EXPRESSED IN SECONDS (PRE-SET AT 3
SECONDS)
P10
TYPE OF UNIT SELECTION
0 - 1
0 = °C - l/min
1 = °F - gpm