User Manual 

Wall hung storage boiler  Low Nox   – Cod. 99960NA – November  2002

 

 

BOILER OPERATION AND ADJUSTMENT PROCEDURES FOR USER 

 

Before turning on the boiler read the following warnings carefully . 

Make sure that the warranty booklet carries the stamp of the CORGI registered technician (you can check this by contacting 
corgi on 01256.372200) responsible for installing the boiler. Installation, starting up for the first time, adjustments and 
maintenance operations must all be carried out solely by qualified technicians. Incorrect installation may cause damage to 
persons, animals or property for which the manufacturer cannot be held liable. 
 

WARNING! 

⇒ 

Do not start the boiler unless you are sure it has been thoroughly tested by an authorised technician. 

⇒ 

Check that the regulations regarding air intakes and ventilation of the room where the boiler is installed have been 
fully complied with. 

⇒ 

The anti-freeze system will come into operation only if the boiler is in the 

 winter ( ) or summer ( ) 

position (with 

selector switch 1 in fig. 1 turned to the summer or winter position) and the gas supply turned on. The manufacturer 
can accept no responsibility for damage to the boiler caused by lack of observation of these requirements.  

⇒ 

If the boiler should freeze up, under no circumstances attempt to turn it on but call the RADIANT HELP LINE – 
(1329.828555) immediately.

 

 

LEGEND (see fig. 1) 

1. 

SUMMER-WINTER ON-OFF SWITCH 

2. 

LOCK-OUT INDICATOR 

3. 

HEATING TEMPERATURE ADJUSTMENT 
KNOB 

4. 

WATER TEMPERATURE ADJUSTMENT 
KNOB 

5. 

SPACE FOR ADDING AN OPTIONAL TIMER 

 
SELF- DIAGNOSTIC LEGEND (see fig. 2) 

6. 

OPERATING/ POWER INDICATOR 

7. 

DOMESTIC HOT WATER OPERATION 

8. 

HEATING OPERATION  

9. 

FLASHING LIGHT DENOTING AIR 
PRESSURE SWITCH FAILURE 

10. 

FLASHING LIGHT DENOTING DOMESTIC 
WATER SENSOR FAILURE  

11. 

FLASHING LIGHT DENOTING HEATING 
SENSOR FAILURE  

12. 

FLASHING LIGHT DENOTING 90° C MAX 
TEMPERATURE SENSOR FAILURE  

13. 

FLASHING LIGHT DENOTING LACK OF WATER IN SYSTEM 

14. 

WATER PRESSURE LEVEL 1 BAR 

15. 

WATER PRESSURE LEVEL 1.5 BAR 

16. 

ELECTRONIC TEMPERATURE INDICATOR 

 

 Turning on procedure for electronic ignition (only for U.k. and Ireland): 

 

turn on the gas cock situated under the boiler grill; 

 

turn selector switch 1 to the   symbol denoting winter (see fig.2);  

 

make sure that 6 light is ON (see fig. 2 pag. I) and the no.14 or no.15 lights are ON (see fig. 2); if light no.13 flashes, it 
means water deficiency in the system: open the tap on the filling loop and fill the system

 

until a pressure of 1.5 bar has been 

reached (light no.15 ON; see fig. 2) and then close the tap.  

 

The automatic ignition system will turn the burner on. 

It may be necessary to repeat the procedure a few times to purge air from the pipes. To repeat the ignition procedure press 
release button 2 (see fig. 1) and then try the ignition procedure once again. If the boiler does not start, press the reset button 
(see fig. 1 pag. I). IMPORTANT should the boiler fail to ignite wait 3 minutes before pressing button again.  
If locking-out persists, turn boiler OFF and call 

RADIANT HELP LINE - 01329.828555.

 

 

6

7

8

9

30

1

2

SELF DIAGNOSTIC

ELECTRONIC WATER

PRESSURE GAUGE

10 11 12

13

50

40

16

60

70

80

3

4

14 15

1.5

1

5

Fig. 1 

Fig. 2 