Disconnect all power before installing or servicing the heating ca-
ble and accessories. Self-regulating heating cable must be ground-
ed properly in accordance with the National Electrical Code (NEC).
Failure to comply can result in personal injury or property damage.
Only a qualified licensed electrical contractor shall install and ser-
vice of self-regulating heating cable and accessories, otherwise the
warranty is voided.
v.10.18.21
Note: All electrical wiring, including Ground Fault Circuit Interrupt-
ers (GFCI), must be done according to the NEC and local codes by a
qualified installer. Article 426 of ANSI/NFPA 70 of National Electri-
cal Code (NEC section 62 of CAN/CSA-C22.1, Canadian Electrical
Code, Part I (CEC) governs the installation of this heat systems.
The IDP-115 downspout hanger can be used with any self-regulating heat
cable. Carefully follow these instructions. Do not use other hardware or
alternate mounting methods which may damage the heating cable and
create an electrical hazard, risk of fire, or poor performance.
Downspout hangers are required to prevent damage to heating cable as it enters or exits the downspout or any other areas where heat
cable is installed over sharp or abrasive surfaces. Downspout hangers can also be used as spacers inside the gutters when multiple runs of
heating cable are used.
Downspout hangers must be installed properly to ensure prop-
er operation and to prevent the risk of electrical hazard or fire.
Follow all design, installation, assembly, and test instruc-
tions carefully.
To minimize the danger of fire from electrical arcing if
the heating cable is damaged or improperly installed ground
fault equipment protection (GFEP) must be used on each heat-
ing cable branch circuit. Arcing may not be stopped by conven-
tional circuit protection.
Damaged heating cable can cause arcing or fire. Do not ener-
gize damaged heating cable. Repair or replace damaged heat-
ing cable prior to applying power.
Do not twist cables during installation or embed them in ther-
mal insulation.
1.
2.
3.
4.
5.
DESCRIPTION:
WARNING:
WARNING:
Read this manual before attempting to install your Radiant Solutions Company products. Incorrect installation could damage the prod-
ucts and will invalidate the warranty.
STEP ONE:
STEP TWO:
For more information, visit www.radiantsolutionscompany.com
SOLUTIONS COMPANY
RADIANT
INSTALLATION MANUAL
IDP-115 Downspout Hanger