33
Information requirements for electric local space heaters
Model identifier(s): KYOTO / AETHEREA
Item
Symbol
Value
Unit
Item
Unit
Heat output
Type of heat input, for electric storage local space heaters only (select
one)
Nominal heat
output
P
nom
See
Tab. 1
kW
manual heat charge control, with integrated thermostat
no
Minimum heat
output (indicative)
P
min
See
Tab. 1
kW
manual heat charge control with room and/or outdoor tempe-
rature feedback
no
Maximum
continuous heat
output
P
max,c
See
Tab. 1
kW
electronic heat charge control with room and/or outdoor
temperature feedback
no
Auxiliary electricity consumption
fan assisted heat output
no
At nominal heat
output
el
max
0,000
kW
Type of heat output/room temperature control (select one)
At minimum heat
output
el
min
0,000
kW
single stage heat output and no room temperature control
no
In standby mode
el
SB
NO WI-FI
0,161
W
Two or more manual stages, no room temperature control
no
el
SB
WI-FI OFF
0,198
W
with mechanic thermostat room temperature control
no
el
SB
WI-FI
CONNECTED
0,250
W
with electronic room temperature control
no
el
SB
WI-FI
ACCESS POINT
0,459
W
electronic room temperature control plus day timer
no
electronic room temperature control plus week timer
yes
Other control options (multiple selections possible)
room temperature control, with presence detection
yes
room temperature control, with open window detection
yes
with distance control option
no
with adaptive start control
no
with working time limitation
no
with black bulb sensor
no
Contact details
Ermete Giudici S.p.A. - via L. da Vinci, 27 - 20090 Segrate (MI) Italy
TABLE 1
KYOTO 7
KYOTO 10
AETHEREA 10
KYOTO 15
AETHEREA 15
KYOTO 20
Heat output
Nominal heat output
P
nom
0,750
1,000
1,500
2,000
Minimum heat output (indicative)
P
min
0,075
0,100
0,150
0,200
Maximum heat output (indicative)
P
max,c
0,750
1,000
1,500
2,000
Summary of Contents for KYOTO 7
Page 4: ...4 1 2 3 4 click click 8 1m 3 m 4m 9...
Page 78: ...78...
Page 79: ...79...