OVERVIEW

1. INSTRUMENT INPUTS:

  The  JX42  features  four 

1/4”  instrument  inputs  for  wired  or  wireless  guitars. 

Any combination of these four inputs can be active at 

the same time, making it easy to switch instruments 

from one song to the next. Large front-panel switches 

turn each input on and off, and the input connections 

are  mirrored  on  the  both  the  front  and  back  of  the 

JX42  for  convenience.  The  optional  JR-5  remote 

footswitch allows hands free operation and includes 

LED indicators to show which guitars are active.

2. AMPLIFIER OUTPUTS:

 A selector switch on the 

front panel of the JX42 silently toggles between two 

1/4” outputs to feed a pair of amplifiers. This feature 

can  also  be  accessed  remotely  using  the  optional 

JR-2  footswitch. A  pristine  Class-A  signal  path  and 

Jensen  transformer  isolation  on  both  outputs  offer 

studio quality sound while eliminating hum and buzz 

caused by ground loops. 

3. TUNER OUTPUTS:

  The  JX42  includes  tuner 

outputs on both the front and back panels. All inactive 

instrument  inputs  automatically  feed  the  tuner 

outputs,  so  a  guitar  tech  can  simply  grab  and  tune 

without disrupting the performance. Both of the tuner 

outputs can be used simultaneously.

4. MIDI INPUT:

 Built in MIDI functionality allows you 

to  use  third-party  MIDI  footswitches  to  control  the 

functions  of  the  JX42  remotely.  Instrument  on/off 

controls, amplifier switching, and the ability to have 

both amplifiers on simultaneously are all available via 

MIDI commands.

INPUT-1

INPUT-2

INPUT-3

INPUT-4

Wireless

Wireless

Wireless

1. INSTRUMENT INPUTS

2. AMPLIFIER OUTPUTS

GUITAR SELECT

AMP SELECT 

3. TUNER OUT

4. MIDI INPUT

OUT-A

OUT-B

The JX42 V2 can be simplified by grouping its features into four main sections: the Instrument Inputs, the Amplifier 

Outputs, the Tuner Outputs, and the MIDI Input.

TUNER

MIDI CONTROLLER

Summary of Contents for X42 V2

Page 1: ...and appearance are subject to change without notice Copyright 2021 Radial Engineering Ltd Radial Engineering Ltd 1165 1845 Kingsway Ave Port Coquitlam BC V3C 1S9 Tel 604 942 1001 www radialeng com Ema...

Page 2: ...ze yourself with the many features available on the JX42 V2 allowing you to get the most out of this powerful switching device If you have any questions that are not addressed by this user guide pleas...

Page 3: ...nd Jensen transformer isolation on both outputs offer studio quality sound while eliminating hum and buzz caused by ground loops 3 TUNER OUTPUTS The JX42 includes tuner outputs on both the front and b...

Page 4: ...be on simultaneously 3 TUNER OUT Buffered unbalanced output to feed a tuner pedal This output is fed by all inactive instrument inputs and can be used simultaneously with the rear panel Tuner output 4...

Page 5: ...ts When a JR 2 remote is connected the front panel amp select switch on the JX42 will be inactive 9 TUNER OUT Buffered unbalanced output to feed a separate tuner This output is fed by all inactive ins...

Page 6: ...JX42 by pressing the corresponding front panel ON switch Each switch is backlit and will illuminate when the input is selected To deselect any instrument press the ON switch a second time The JX42 all...

Page 7: ...he amp outputs are muted the Amp Select Switch will not be illuminated Please see the JR 2 and MIDI sections of this manual for further details THE TUNER OUTPUTS The JX42 has two tuner outputs with on...

Page 8: ...o be operated in BANK mode which stores up to four combinations of input on off settings eliminating excess toe tapping during complex performances When the JR 5 is operating in BANK mode the JX42 fro...

Page 9: ...REMOTE FOR AMPS The JX42 is also compatible with the optional Radial JR 2 remote footswitch which can be used to control the amplifier outputs from up to 300 feet away Connect the JR 2 remote to the r...

Page 10: ...ic channel is particularly useful when linking multiple MIDI devices as they can all be set to only respond to changes on their assigned channel Some MIDI equipment will default to OMNI mode when firs...

Page 11: ...MIDI IMPLEMENTATION CHART The JX42 is setup to respond to both MIDI Control changes and Program changes Control changes can select both guitars and amplifiers on the JX42 while Program changes are res...

Page 12: ...dB 0dBv Gain 0 3dB Maximum Input 18dBu Output 1 THD 1kHz 17dBu Output 0 1 THD 1kHz Total Harmonic Distortion Noise 0 001 100dB 1kHz 0dBu Total Harmonic Distortion 0 0006 105dB 1kHz 0dBu Signal to Nois...

Page 13: ...True to the Music Radial Engineering Ltd JX42 V2 Owner s Manual 12...

Page 14: ...True to the Music Radial Engineering Ltd JX42 V2 Owner s Manual...

Page 15: ...True to the Music Radial Engineering Ltd JX42 V2 Owner s Manual...

Page 16: ...and the dealer name must accompany any request for work to be performed under this limited and transferable warranty This limited warranty shall not apply if the product has been damaged due to abuse...

Reviews: