17
EN
19
(11)
(12)
(13)
(14)
(2)
(3)
(4)
(5)
18
7.10 Mounting the roller capsule (4)
1.
Slide the roller capsule
(4)
into the winding shaft
(5)
and subsequently place the ball bearing
(2)
onto the
axle pin
(3) of the roller capsule
.
7.11 Mounting the motor into the bearings
i
The tubular motors can be fitted into the
click bearing
(13)
in 4 positions.
The motors can be released from the
click bearing
(13)
at any time by means
of expanding the retaining spring
(14)
.
7.11.1 Mounting into the drive bearing as a click bearing (13)
1.
Press the drive head
(12)
lightly into the click bear-
ing
(13)
until it engages. The set button
(11)
must
be easily accessible.
Hook the drive head
(12)
into the corresponding drive bearing and secure, for example, with a cotter pin.
7.11.2 Mounting in other drive bearing versions
WARNING!
WARNING!
Risk of short-circuit resulting from water in the
event of improper cabling.
Never lay the motor cable
(15)
vertically upwards
otherwise water may collect on the cable and run
into the motor, leading to damage.
Lay the cable in a loop. The loop will cause any
water on the cable to collect at the lowest point,
from where it can drain off.