background image

NOTE!

If the button on the motor head is not acces

-

sible, you can alternatively enter the DuoFern 

code on the manual central operating unit 

under menu item 2-2 and use the up key to 

switch login mode to ON. 

The DuoFern code is only active for 2 

hours after switching on the power supply.

RolloTube DuoFern tubular motor

Brief instructions for installation and initial commissioning

These instructions describe the simplest way to configure the RolloTube DuoFern tubular motor. Please ensure that you refer to the full operating 

instructions for the safety instructions, additional configuration options, connection options and information about resetting the system.

CAUTION!

Risk of crushing injuries due to rotating shaft!

There is a risk of crushing injuries to the hands when working with the roller shutter box open.

• 

never reach into the area of the rotating union when the motor is running.

Important

The roller shutter curtain must be equipped with a stopper or end rail in order to 

undertake the subsequent automatic end point setting (Fig. 1).

In addition, the catch must be mounted so it can free-wheel. Sufficient free-

wheeling is given if the catch can be easily turned back and forth (supplied state 

Fig. 2).

Stopper

(Fig. 1)

(Fig. 2)

Electrical connection

DANGER!

Risk of fatal electric shock!

Danger due to electric shock when working on 

all electrical systems. 

• 

Only allow 

qualified specialists

 to work on 

the electrical systems.

• 

Switch off the power supply

 prior to car

-

rying out installation work.

• 

Keep moisture away from live equipment.

230 Volt~

50 Hz

Logging in

1.  Press the button on the motor head until the set button 

LED flashes red and the motor advances briefly. You 

now have 60 seconds to activate login mode from 

one 

of the following transmitters.

1.  Open the menu of the central operating unit by 

pressing the 

M button

.

2.  Select system settings  

 and confirm with 

OK

Select menu item 2-1 connect / disconnect

3.  The number of assigned devices is displayed.

4.  Now press the 

Up key

, in order to activate login 

mode on your manual central operating unit.

5.  Subsequently select the group and member number 

and confirm in each case with 

OK 

until 

assigned 

appears.

6.  Exit the menu by pressing the

 M button

.

Briefly press 

the "connect

button" (see 

arrow). Subse

-

quently select 

channel key 

1-6.

Press and 

hold the two 

above buttons 

simultane

-

ously until the 

green LED 

flashes

Manual central operating unit

Manual transmitter

Wall transmitter

or

or

The motor acknowledges successful assignment by starting up briefly and the set button LED turns green.

Now move the motor upwards using the previously assigned transmitter (de-

pending on the installation, it may be necessary to press the up or down button).

The end point setting and the assignment for the direction of rotation is carried 

out automatically (please refer to the figure for the program sequence). 

IMPORTANT!  Please do not press any other buttons during the  

 

configuration process!

The motor is now 

fully configured and is 

ready for operation.

End point setting

LED

IMPORTANT!

1.  First move the roller shutter upwards when automatically 

adjusting the end points.

2.  The roller shutter should remain at the upper  end point 

following automatic adjustment.

The end points cannot be correctly adjusted if the two condi

-

tions are not met. In this case, reset the tubular motor to its 

factory settings and repeat the process.

VBD 560-9-1 (05.18)

L1

N

PE

M

~

5

2 1

3 4

1 = L1 phase = black

2 = N neutral = blue

3 = External switch = white/grey

4 = Antenna = brown

5 = PE protective earthing conductor = green-yellow

1

2

3

4

5

IMPORTANT!

  If the "external switch" lead is not used, then it must be connected 

 

 

to the neutral conductor!

L1 

N

PE