Model DAPCKP
DAPcheck Plus 
DAP Analyzer

Instruction Manual

Summary of Contents for DAPCKP

Page 1: ...Model DAPCKP DAPcheck Plus DAP Analyzer Instruction Manual ...

Page 2: ......

Page 3: ...under the Following Patent Pat No 7 413 345 Radcal Corporation 426 West Duarte Road Monrovia CA 91016 4591 USA USA 626 357 7921 Fax USA 626 357 8863 email Service radcal com www radcal com Radcal Part MNL DAPCKP 4077023 Rev Printed Nov 2012 ...

Page 4: ...ic meaning and the reader should be aware of their significance Attention Used where there is a risk of damaging the DAPcheck Plus by incorrect handling or operation error Note Used where information is provided to aid better understanding of the DAPcheck Plus or its use 4 ...

Page 5: ...ping 6 Cleaning 6 Storage conditions of application 6 Disposal 7 System description 8 Introduction 8 Construction 8 The Ion chamber 8 The radiation target 8 Preparations for operation 9 Preparation 9 Power on test 9 Stabilization time 9 Operation 10 Technical specifications 11 Warranty 15 5 ...

Page 6: ...re 0 C 50 C Relative air humidity 10 80 max 20 g m3 non condensing Cleaning When cleaning the ionization chamber no abrasive cleaners and no organic solvents or cleaning agents containing solvents e g petroleum ether alcohol must be used The enclosure of the DAPcheck Plus can be cleaned by wiping with a damp cloth containing a mild washing up liquid solution Storage conditions of application Nomin...

Page 7: ...Disposal The DAPcheck Plus must be disposed of in accordance with the applicable national regulations or returned to the manufacturer A WEEE manual is available from Radcal 7 ...

Page 8: ... incorporates a beam alignment target Note There are no user accessible components within the housing The Ion chamber The ion chamber is suspended within the protective housing to minimize disturbance during positioning the DAPcheck Plus in the radiation beam The radiation target A target assembly is provided to assist with alignment to the radiation beam Where a light field is not available a mat...

Page 9: ...e measuring system includes an automatic power on test during which the function of the ionization chamber and all electronic systems are checked Stabilization time The ionization chamber is a highly sensitive detector which must stabilize following application of the ionization potential in order to meet the specified performance see page 11 The period of time required for this process is known a...

Page 10: ...ced on the desktop automatically AccuGoldExcel is an Excel interface for Accu Gold and the software is installed as an Excel add on A quick start manual can be found under Manuals in the same folder Use of AccuGoldExcel requires that Microsoft Excel is already installed on your computer To run the software open the Accu Gold Excel folder using the shortcut or navigate to Program Files Radcal AccuG...

Page 11: ... 10 mGy min 15 x 15 cm field 80 kVp 2 5 mm Al filtration Digital Resolution Dose area product rate 1μGy m2 min to 0 91 Gy m2 min Rated range of use Tube voltage 40 150 kV Automatic Temperature and Pressure Correction Pressure Temperature Air Humidity 80 106 kPa 15 to 35 C operating 0 to 50 C storage 10 80 relative humidity max 20 g m3 non condensing Ionization Chamber Response vs radiation quality...

Page 12: ...Connection to Accu Gold Digitizer One meter disconnect cable with 2 connectors Protection Class acc IEC 60529 IP 41 Weight 2 3 kg 5 1 lbs Dimension L x W x H 350 mm x 410 mm x 35 mm 12 ...

Page 13: ...Support Elevation Stand Foam Elevation Support Stand fits inside the interior of the Carry Case lid 13 ...

Page 14: ...14 ...

Page 15: ...cement parts nor shall Radcal be liable for any defective material replaced without Radcal s consent during the period of this warranty Radcal reserves the right to perform warranty services at its own factory Non Warranty Repairs The calibration of this instrument was correct within specified limits when the instrument left our factory Radcal cannot be responsible for injury or damage resulting f...

Page 16: ...r sole responsibility that the model DAPcheck Plus Measurement System conforms to the following product specifications EMC EN50081 2 EN55011 Class A EN61000 4 2 EN61000 4 3 EN61000 4 8 IEC60601 1 IEC60601 1 2 QA Manager Date July 20 2007 Radcal Corporation 426 West Duarte Road Monrovia CA 91016 4591 USA 16 ...