Manual Configuration
For simpler installations, the use of the infra-red may
not be required.
SpeechPOD can be set up manually by selecting
the DIL switch settings shown across. Messages, vol-
ume and repeat functions are all programmable .
Of course, timer settings and other high end func-
tions cannot be selected manually.
1 = O n ( u p ) 0 = O f f ( d o w n )
1
2
3
4
5
6
7
8
In f r a r e d R e m o t e
E n a b le d
0
D is a b le d
1
S o u n d O u t p u t T y p e
A le r t T o n e
0
S p e e c h
1
M e s s a g e R e p e a t P l a y s
1
0
0
( o r T o n e )
2
0
1
3
1
0
4
1
1
M e s s a g e S e le c t
1
0
0
0
2
0
0
1
3
0
1
0
4
0
1
1
5
1
0
0
6
1
0
1
7
1
1
0
B a t t e r y M o n it o r in g
9 V B a tte r y
0
6 V B a tte r y
1
S e ttin g :
1
1
0
0
0
0
0
0
IN T E R N A L S W IT C H S E T T IN G S
F a c t o r y D e f a u lt S e t t in g s :
M a n u a l
IR R e m o te D is a b le d , S p e e c h O u tp u t , 1 M e s s a g e P la y , M e s s a g e 1 , 9 V B a tte r y
I n f r a r e d R e m o t e /P C O n ly
A u to m a tic S w itc h O f f T im e r : C o n tin u o u s O p e r a tio n
M e s s a g e R e p e a t D e la y T im e r : Z e r o ( Im m e d ia te O p e r a tio n )
Product Specifications:
Voltage
Internal:
9V
PP3
Alkaline
Battery
External:
6
–
12V
DC
Current
Standby Mode:
90uA @ 9V supply
Messaging
Mode:
80mA
@9V
supply
PIR Range
0 < 5m with a 70 degree spread
Temperature
-10 to +50 C
Humidity
0 – 95% non-condensing
Sound Output
89 dBa max. (Message dependant)
Weight
0.45Kg
Dimensions
150mm x 100mm x 50mm
Normally used for wet and slippery floor messages,
SpeechPOD can be set to play a message whilst the
floor is wet and then turn off after the timer has reached
zero. If set at zero SpeechPOD is ON
USER GUIDE NOTES
Normally used for setting a delay between message
plays. In mode 1 SpeechPOD will play the selected mes-
sage immediately on activation, but will then not play
again until the MODE 1 timer is zero
NOTE: You cannot use Modes 1 and 2 together
Normally used for setting a delay between message
plays. In mode 2 SpeechPOD will not play the selected
message immediately on activation, but will play it when
the MODE 2 timer is zero
NOTE: You cannot use Modes 1 and 2 together
To avoid message fatigue, the user can program all
seven messages on the same theme phrased differently.
With MODE 3 ON each message will be played in turn on
subsequent activations.
Used in conjunction with MODE 0. If you do not want
SpeechPOD to turn off after the time period selected in
MODE 0, then turning ON MODE 4 will ensure that after
MODE 0 time out SpeechPOD will not turn off, but will
default to play message 1.