SPEECHPOD CONFIGURATION AND SETUP PROCEEDURE

 

 

Once  you have  accessed  the  configuration menu  by  pressing  the  SpeechPOD  button,  you have  access  to  all  the 
functions relevant to the SpeechPOD element.. All these functions are shown below, but remember if you do not 
have a particular element (e.g. PIR Motion sensor) on the device you have purchased, you will not be able to set 
the configuration menu for this element.

 

 

Pressing the LANGUAGE button UP or DOWN will scroll through the list of available languages and the 
device will tell you which language is currently selected. The languages programmed by the factory are 
as follows and once selected all the menu settings will be spoken in the selected language.

 

 

“ENGLISH” ; “FRANCAIS” ; “DEUTSCHE” ; ESPAŇOL ; AMERICAN ; OTHER

 

 

Pressing the MESSAGE button UP or DOWN will scroll through the list of available messages you have 
programmed in the Cig

-

Arrête® folder on the SD Flash Card. You can program several messages in this 

folder  and  use  the  MESSAGE  button  to  select  the  particular  message  to  be  played  in  the  event  of  a 
smoking detection. Please note  that  whichever message you select will be played for an alarm event 
from either the flame detector, or the smoke detector.

 

 

Pressing  the  MODE  button  UP  or  DOWN  will  scroll  through  the  options  for  the  available  SpeechPOD  func-
tions. The options are shown below with a brief description for each one. The MODE button works together 
with the TIME DELAY button which selects the various options or time delays for each MODE selected.

 

 

“CLEANER MODE—PLEASE SELECT TIME TO OFF” 

 

Used  by cleaning  staff  to  change  the  normal  operational  mode  to  play  a  message  alerting  partially sighted 
people that the floor may be wet and slippery. Use the TIME DELAY button to select the time required for the 
floor to dry (10 mins to 60 mins) After the time period SpeechPOD will return to its normal mode and time 
delays etc.

 

 

“DELAY AFTER ACTIVATION—PLEASE SELECT TIME DELAY”

 

SpeechPOD will play the selected message immediately sensing motion, but will not play any message again 
for a time period which is selected by pressing the TIME DELAY button UP or Down. Typically this function is 
used for infection control messages to use hand gel prior to visiting patients and relatives. 

 

 

“DELAY BEFORE ACTIVATION—PLEASE SELECT TIME DELAY”

 

SpeechPOD  will  be  activated  on  sensing  motion  but  will  not  play  the  selected  message  for  a  time  period 
which  is  selected  by  pressing  the  TIME  DELAY  button  UP  or  Down.  Typically  this  function  is  used  for  hand 
washing, where a person enters a washroom and the product waits for 60 seconds before reminding them 
about the importance of hand hygiene.

 

 

“SEQUENTIAL MESSAGES—PLEASE SELECT ON OR OFF”

 

Press the TIME DELAY button to switch this ON or OFF. When ON, at the first detection of motion SpeechPOD 
will play the first message in the SPOD folder, on subsequent activations, the next message in the folder will 
be played and so on. This avoids any message fatigue and always makes the announcement fresh.

 

 

“MESSAGE REPEATS”

 

Once you have pressed the MODE button above, you can press the TIME DELAY button UP or DOWN to scroll 
through  the  MESSAGE  REPEATS  (the  number  of  times  that  the  device  will  play  the  message  in  alarm)  The 
factory default setting is ONE. The options available are:

 

 

“OFF” ; “ONE” ; “TWO” ; “THREE”

 

 

Once  you  have  configured  the  SpeechPOD®  element  present  on  your  device,  press  the  SPEECHPOD  button 
again to return to ‘RUN MODE’ which makes the device run normally and ready to generate alarm conditions. 
On exiting the configuration mode the device will provide the following message:

 

 

“DEVICE CONFIGURED”

 

+

 

GENERAL OVERVIEW OF PROGRAMMING FUNCTIONS

 

 

The chart below provides at a glance all the programming functions detailed in the next few pages of the guide.

 

Summary of Contents for CSA-POD24

Page 1: ...A POD is normally supplied with an on board infra red PIR motion sensor as its detection device You can however trigger the SpeechPOD by other sources instead or in addition to the PIR motion sensor Examples of these may be Door Contact Pressure mat alarm output from security fire or Building Management Systems or any other device that has a Clean or Volt Free Output Simply connect the Normally Op...

Page 2: ...trigger unwanted alarms 5 For SpeechPOD installations if the number of message plays is expected to be high consider using an external 9 24Vdc power supply to avoid draining of batteries RADIO COMMUNICATION SETUP Not applicable to 24Vdc models The radio communication modules if fitted only transmit alarm conditions from the Cig Arrête elements ie Flame and smoke sensors They do not transmit any PI...

Page 3: ... floor to dry 10 mins to 60 mins After the time period SpeechPOD will return to its normal mode and time delays etc DELAY AFTER ACTIVATION PLEASE SELECT TIME DELAY SpeechPOD will play the selected message immediately sensing motion but will not play any message again for a time period which is selected by pressing the TIME DELAY button UP or Down Typically this function is used for infection contr...

Page 4: ...W CIG ARRETE CONFIGURATION AND SETUP PROCEEDURE Once you have accessed the configuration menu by pressing and holding the Cig Arrête button you have access to all the functions relevant to your particular device All these functions are shown below but remember if you do not have a particular element e g Flame detector on the device you have purchased you will not be able to set the configuration m...

Reviews: