All possible parameters
Tables 2 to 7, describe all the parameters that can be measured and calculated by the
WaveGuide Height & Tide system.
Adding parameters that are not available by default is possible. Added parameters will
run in the background and will be available for storage and subscription, yet they will
not be visible from the user interface. It is strongly recommended that the user requests
the changes when the WaveGuide Height & Tide system is ordered such that all necessary
tests can be performed at Radac. Post-delivery adjustments to the available parameters
are possible upon request, but not recommended.
Name Description
Unit
heave Instantaneous water level
cm
Table 2: Raw data at 10 [Hz]
Name Description
Unit
Czz5
Energy density spectrum from 0 to 500 [mHz] in steps of 5 [mHz] (101 values)
cm
2
/Hz
Czz10 Energy density spectrum from 0 to 500 [mHz] in steps of 10 [mHz] (51 values)
cm
2
/Hz
WTBH Table of wave heights
cm
WTBT Table of wave periods
s
Table 3: Spectra and wave tables
Name
Description
Unit
Hm0
Significant wave height from M0
cm
M0
Band energy from Czz10(f) in the range f =[30-500] mHz
cm
2
M0_M
Band energy from Czz10(f) in the range f =[30-1000] mHz
cm
2
Hm0_M
Significant wave height from M0_M
cm
Tm02
Average period from M0 and M2 in the range f=[30-500] mHz
s
Tm02_M
Average period from M0 and M2 in the range f =[30-1000] mHz
s
TE0
Band energy from Czz10(f) in the range f =[500-1000] mHz
cm
2
TE1
Band energy from Czz10(f) in the range f =[200-500] mHz
cm
2
TE1_M
Band energy from Czz10(f) in the range f =[200-1000] mHz
cm
2
TE2
Band energy from Czz10(f) in the range f =[100-200] mHz
cm
2
HTE3
Wave height from TE3 (Band energy from Czz10(f) where f =[30-100] mHz)
cm
Fp
Frequency f where Czz10(f) has its maximum in the range f =[30-500] mHz
mHz
Fp_M
Frequency f where Czz10(f) has its maximum in the range f =[30-1000] mHz
mHz
AV10_H
Number of degrees of freedom in the energy density spectrum (4 * Ndlr_H)
−
HS7
Wave height from band energy from Czz5(f) in the range f =[30-142.5] mHz
cm
Tm0_1
Minus first moment period from M-1 and M0 in the range f =[30-500] mHz
s
Tm0_1_M Minus first moment period from M-1 and M0 in the range f =[30-1000] mHz
s
Table 4: Spectral processing parameters
23