INSTALLATION
General
Installation must be carried out in accordance with these instructions, and must be
conducted by designated, qualified and competent personnel.
Installations must comply with Water Regulations (Bye-Laws, Scotland), and any
Local Regulations and Building Regulations in force at the time of installation.
Before installation carefully inspect the new fixture for any signs of damage.
1.
Supply pipes must be flushed to clear debris before connecting the
shower fittings. Layout and sizing of pipework must be such that when
other services are used, pressures do not fall below the recommended
minimum at the shower fitting causing the spray pattern to collapse.
2.
Avoid a position in which the product could become frozen.
3.
Do not
fit any form of flow control in the outlet pipework if the shower fitting is
installed in conjunction with a product that requires the fitting to act as a vent
(e.g. an electric shower).
4.
Do not use excessive force when making connections.
5.
Maintained pressures above 2 bar at the shower fitting, could result in excessive
spray forces.
6.
All models have a mounting bush, which is secured to the wall with two screws
(wall plugs and screws provided, suitable for standard masonry). The spray
body is retained on the mounting bush by a recessed hexagon-drive grubscrew
(Hexagonal Wrench supplied).
7.
The Rada VR2-CC, VR2-RS and VR2-ES may be bolted through the mounting
bush onto the Rada VR Security Kit (optional), which is mounted within the wall
or behind a panel, for extra mounting security.