rada TF31 Product Manual Download Page 11

11

Spare Parts Diagram

SPARE PARTS

Spare Parts List

021 61

Actuator Assembly TF31/1

021 62

Actuator Assembly TF31/2

021 63

Actuator Assembly TF31/3

192 69

Union Assembly

555 19

Valve Mounting Adaptor

622 55

Back Nut

624 09

Union Nut

625 22

Lock Nut

631 39

‘O’ Seal

868 10

Guide

631 39

021 61
021 62
021 63

192 69

555 19

624 09

868 10

625 22

622 55

www.divapor.com

Summary of Contents for TF31

Page 1: ...UAL TF31 DUCT MOUNTED TIMED FLOW CONTROLLER IMPORTANT Installer This Manual is the property of the customer and must be retained with the product for maintenance and operational purposes w w w d i v a...

Page 2: ...knesses between 206 mm and 246 mm 8 and 9 DESCRIPTION SAFETY WARNINGS Rada products are precision engineered and should give continued superior and safe performance provided 1 They are installed commi...

Page 3: ...Rates 5 TemperatureRange 5 Connections 5 DIMENSIONS 6 PACK CONTENTS 7 INSTALLATION General 8 Procedure 8 MAINTENANCE General 10 Preventative Precautionary Maintenance 10 Lubricants 10 Maintenance Proc...

Page 4: ...Warning Continued use of this product in conditions outside the limits listed in this section can severely affect the performance and reduce the effective service life and can present potential risk t...

Page 5: ...open outlet Temperature Range Suitable for applications requiring water temperatures up to 70 C Connections 15 mm compression Alternatively a 3 4 BSP male parallel thread is available by removing the...

Page 6: ...6 DIMENSIONS Model Overall Length A Wall Thickness B TF31 1 TF31 2 TF31 3 445 380 340 206 246 142 182 100 140 49 mm 86 mm A B 50 mm Diameter 32 mm Diameter w w w d i v a p o r c o m...

Page 7: ...es and to confirm that the parts are included 1 x Actuator Assembly Documentation 1 x Product Manual 1 x O Seal 1 x Timed Flow Valve 1 x Valve Mounting Adaptor 1 x Union Assembly 1 x Guide 2 x Locknut...

Page 8: ...through the hole from the front of the wall having first made sure that the O seal is correctly installed 3 Firmly fix the actuator assembly into the wall using the 1 2 backnut supplied ensuring that...

Page 9: ...The valve will not function correctly if the water does not flow in the direction indicated 8 Connect inlet and outlet pipework using the compression fittings supplied To commission Rada TF503 Timed...

Page 10: ...age corrosion etc Maintain or renew as necessary Lubricate applicable components using silicone only based lubricant Lubricants Important Use silicone only based lubricants on this product Do not use...

Page 11: ...1 62 Actuator Assembly TF31 2 021 63 Actuator Assembly TF31 3 192 69 Union Assembly 555 19 Valve Mounting Adaptor 622 55 Back Nut 624 09 Union Nut 625 22 Lock Nut 631 39 O Seal 868 10 Guide 631 39 021...

Page 12: ...n no way affected by this guarantee After Sales Service how we can help you We have a network of fully trained staff ready to provide assistance should you experience any difficulty operating your Rad...