MAINTENANCE
Spray Plate Cleaning
Many household cleaners contain abrasives and chemical substances, and should not
be used for cleaning plated or plastic fittings. These finishes should be cleaned with
a mild washing up detergent or soap solution, and then wiped dry using a soft cloth.
1.
Unscrew and remove the spray
plate assembly.
2.
Remove the 'O' seals.
3.
Clean all the components with a stiff
brush. If necessary use a plastic
kettle descalent in accordance with
the manufacturer's instructions.
Flush thoroughly with water before
the shower is used.
4.
Refit the components in reverse
order.
5.
Install the spray plate assembly.
Spray Plate
Spray Plate Assembly - Removal and Installation
The procedure for the removal and installation of the spray plate assembly is identical
for both the handset and the bir assembly. The handset procedure is described below.
Removal
1.
Tur n the adjuster r ing fully
anticlockwise.
2.
Unscrew the spray plate in an
anticlockwise direction. The 'O'
seals will provide some resistance.
Installation
3.
Make sure that the four 'O' seals
are located correctly.
4.
Turn the flow divertor fully clockwise.
Caution!
Do not over tighten the
spray plate.
5.
Carefully screw the spray plate
assembly on to the flow divertor.
The 'O' seals will resist the rotation
of the spray plate.
Handset Body
Assembly
'O' Seal
'O' Seal
Spray Plate
Assembly
Flow Divertor
'O' Seal
'O' Seal
'O' Seals