Status IDs: 

The Status ID represents action of the LED lights above the toggle switches. The Status 

ID can be used to simply monitor the status of the toggle switch (

Switch On x0

) or to indicate the 

status of any selected output by selecting the channel in the pull-down menu desired to monitor.  The 

Status ID can monitor any selected output channel, regardless of the output channel the switch 

actually controls. 

o

 

No Light - indicates output channel is off 

o

 

Green Light - indicates output is on with no delays or blown fuses 

o

 

Orange Light - indicates output has a delay in effect, either waiting to turn on, or waiting to 

turn off. 

o

 

Red Light - indicates a blown fuse. 

 

NOTE:  The Status ID is not selectable for the push button light. This light has two functions: 

1.

 

Shows the operation of the push button (no light off, green light when pushed) 

2.

 

Shows switch panel has power by a green blink approximately every 4 seconds.   

  

 

Switch Bus Terminating Resistor: 

Determines if the switch panel is internally terminated. 

Terminating resistor should be ON if one switch panel is installed. If more than one switch panel is 

installed, the last switch panel should have the terminating resistor turned on, all others should be 

turned OFF. The SmartWire unit has a setting for its Terminating resistor that needs to be turned ON 

and the last Switch Panel or Switch Module should have its Terminating resistor turned ON. 

Buttons (lower right of window):  

 

Start Real-Time Display: 

Shows real-time data for this one particular window.  

 

Send Configuration: 

Sends the windows current values of this channel to the SmartWire

 

 

Read Configuration:

 Reads the values from the SmartWire and populates the window with the 

currently programmed values of this channel. 