5
RaceAmerica Model 2650 Series XL Advanced
2650 XL Advanced Quick Start Guide
This Quick Start guide can be helpful to use as a set of steps to follow for relatively
experienced operators of the XL Advanced system.
1
Set up timing system hardware and cabling on race surface
2
Power on all Infra-red Beam Emitter units
3
Connect all peripheral devices such as printers and scoreboards
4
Power on all printers and scoreboards; observe scoreboards for
proper power up sequence.
5
Power on timing system at the Tree; observe light sequences for
proper power up sequence; press # for Stage status.
6
Go into Alignment Mode (*5) and check alignment at all sensor
locations. No counting digits means everything is aligned.
Exit Alignment Mode (#) when done. Turn off sensor test for sensors not
available (*4 SYSTEM)
7
Go into System Config (*8) to set line feeds to eject a timeslip, timeslips
to auto print, Pre-Stage light functionality.
8
Select PRO of FULL starting lights (3)
9
If running brackets on model 2650B, enter Dial-In times (6)
10
If printing results or sending to a PC, enter Car # (9)
11
Stage racers
12
Start race (0) or use optional Starter’s Button
13
Press # to return to Stage status and clear last race
14
Next Race? Go to (8) or (11)