User’s Manual
47
5.2.5 Analog Inputs (RCM4000 only)
Use this function to configure the A/D converter. This function will address the A/D converter in
Register Mode only, and will return an error if you try the Direct Mode. Appendix B.4.3 provides
additional addressing and command information.
unsigned int anaInConfig(unsigned int
instructionbyte, unsigned int cmd, long baud);
ADS7870 Signal
ADS7870 State
RCM3400 Function/State
LN0
Input
AIN0
LN1
Input
AIN1
LN2
Input
AIN2
LN3
Input
AIN3
LN4
Input
AIN4
LN5
Input
AIN5
LN6
Input
AIN6
LN7
Input
AIN7
/RESET
Input
Board reset device
RISE/FALL
Input
Pulled up for SCLK active on rising edge
PIO0
Input
Pulled down
PIO1
Input
Pulled down
PIO2
Input
Pulled down
PIO3
Input
Pulled down
CONVERT
Input
Pulled down when not driven
BUSY
Output
PE0 pulled down; logic high state converter is busy
CCLKCNTRL
Input
Pulled down; 0 state sets CCLK as input
CCLK
Input
Pulled down; external conversion clock
SCLK
Input
PB0; serial data transfer clock
SDI
Input
PC4; 3-wire mode for serial data input
SDO
Output
PC5; serial data output /CS driven
/CS
Input
BUFEN pulled up; active-low enables serial interface
BUFIN
Input
Driven by VREF
VREF
Output
Connected to BUFIN and BUFOUT
BUFOUT
Output
Driven by VREF
Summary of Contents for RabbitCore RCM4000
Page 6: ...RabbitCore RCM4100...
Page 12: ...6 RabbitCore RCM4000...
Page 20: ...14 RabbitCore RCM4000...
Page 46: ...40 RabbitCore RCM4000...
Page 68: ...62 RabbitCore RCM4000...
Page 82: ...76 RabbitCore RCM4000...
Page 96: ...90 RabbitCore RCM4000...
Page 114: ...108 RabbitCore RCM4000...
Page 118: ...112 RabbitCore RCM4000...
Page 122: ...116 RabbitCore RCM4000...
Page 124: ......