VAN GARAGE LIGHTER
(
continued
)
THESE INSTRUCTIONS
DO NOT COVER ALL DETAILS OR
VARIATIONS IN EQUIPMENT, NOR DO THEY PROVIDE FOR
EVERY POSSIBLE CONTINGENCY TO BE MET IN CONNEC-
TION WITH INSTALLATION, OPERATION OR MAINTENANCE.
Check that:
1. Proper lamp is installed. Lamp is not faulty.
2. Line voltage at the fixture is proper.
3. Fixture is wired properly.
4. Fixture is grounded properly.
TROUBLESHOOTING CHECKLIST
CLEANING
CAUTION: Be sure fixture temperature is cool enough to
touch. Be sure power is off.
Clean reflector and refractor with a cloth moistened with
non abrasive glass cleaning solution.
RE-LAMPING
CAUTION:
Prior to installing, check that the lamp is of proper type and wattage. Observe lamp manufacturer’s recom-
mendations on lamp operation, ballast type and burning positions. Disconnect power. Make sure fixture and lamp are cool
enough to touch.
1. Loosen screws holding refractor.
2. Remove refractor and replace lamp.
3. Close refractor and tighten screws.
WIRING
Use supply wire rated for 90°C.
Make sure the supply voltage is compatible with the unit. Multi tap
units may be used with a choice of 120v, 208v, 240v and 277v,
provided that proper ballast leads are connected in the field. Units
built for a specific voltage are factory-wired for the requested voltage.
1. If other than 120V, connect the appropriate ballast
lead to the black supply lead. Cap the 120v lead.
2. Connect the common ballast lead to white
supply lead.
PHOTOEYE INSTALLATION
A photoeye control may be installed in the field.
1. Remove reflector and refractor.
2. Remove close-up plug on desired side of fixture.
3. Install Photoeye and wire as per diagram.
(+) LINE
RED
(–) COMMON
WHITE
SUPPLY
BLACK
LIGHT
FIXTURE
PHOTOEYE
© RAB Lighting, 9464-0 7/04
EASY INSTALLATION & PRODUCT HELP
Fax Back
Tech Help Line
Faxed Tips & Specs,
Call our friendly experts.
24 hours/day.
8AM - 5PM ET Mon. - Fri.
888 RAB-1236
888 RAB-1000
www.rabweb.com
Visit our internet site for
Your questions and requests
color product photos
will be answered promptly.
and installation tips.
RAB Lighting
170 Ludlow Avenue Northvale, New Jersey 07647 U.S.A.
RA
B
MAKES
IT
EASY!
LIGHT
FIXTURE
BLACK (+) LINE
WHITE (–) COMMON
GROUND
SUPPL
Y
REPLACEMENT LAMPS
Metal Halide
High Pressure Sodium
ANSI ANSI
Wattage
Catalog #
Code
Wattage
Catalog #
Code
150
LMH150
M107
150
LHPS150
S55
175
LMH175
M57
200
LMH200MEDPS
M136
Induction
Compact Fluorescent
Wattage
Catalog #
Wattage
Catalog #
55 LQL55
60
LCFL60
85 LQL85
3. Fixture ground wire must be connected to supply
ground.
4. All unused leads must be capped and insulated.
GROUND