10. Twist on wire nuts, secure with
electrical tape.
11. Put round gasket between sensor
assembly and mounting plate. Use
keyhole slots to secure sensor assembly
to mounting plate. Use silicone sealant
around all openings if necessary.
12. Aim sensor. Perform Walk Test, see
section, “Aiming and Walk Testing”
on page 9.
13. Put lens cover back on Tuff Dome
using (3) screws.
14. Turn on power.
5
Red
Tuff Dome
Black
White
Power In
Basic Wiring Diagram
Tuff Dome Assembly
Vandalproof Installation
Screws:
Tuff Dome sensors are shipped with
stainless steel screws holding the
plastic lens on the front of the sensor.
If desired, you may install vandalproof
screws and tighten with Hex wrench
(screws and wrench supplied).
Plugs:
Tough Dome has three 1/2” plugs in
the die cast housing of the sensor. A
unique feature of these plugs is that
you may insure a vandalproof case
by removing the plugs, turning them
around, and re-installing the plugs from
the back of the Tuff Dome sensor (if you
are not using the holes for
lighting fixtures).
The reversed plugs do not have
screwdriver slots which reduce the
chance of tampering.
Gasket
Gasket
Mounting Plate
Sensor assembly
Lens cover
6
Wiring more than one sensor
together is recommended only for
the experienced installer because
it becomes difficult to trobleshoot.
Single sensors that control their
own lights pinpoint movement
more accurately and operate
better.
Sensors should not be installed on
a circuit that also feeds motor
loads such as HVAC equipment,
kitchen appliances, or garage door
openers. If voltage varies signifi-
cantly from 120 volts, sensors
may malfunction.
Black
Black
Red
Red
Black
Black
White
White
White
White
White
Power In
Power In
Power In
.1µF
400V DC
Capacitor
Black
Tuff Dome
Wiring Diagrams
To override
sensor with a
manual switch
To switch more than rated load
(Relay model only)
Hi/Lo sensors can not accept an
auxiliary relay to increase their
switching capacity.
Multiple Sensors:
Power Quality:
Relay rated to
handle load
required