background image

7

How are the Time, Sensitivity and
Photocell adjusted?

• Time Control: Sets the time that
lights will remain on after the Detection
Zone is vacated from approximately
5 seconds to 15 minutes. Use the
adjustment tool provided to turn
clockwise to increase the time.
• Factory Setting: 5-8 minutes.

• Photocell Control: For night only
operation, use the tool provided or a
small screwdriver to turn the Photocell
Control all the way counter-clockwise
(to the moon symbol). For operation in
low level lights, turn the knob all the
way  clockwise (to the sun symbol).
Adjust counter-clockwise to have the
sensor come on later at dusk, 
clockwise to have it come on earlier.
Hi/Lo Model: Turning photocell 
control will show when the sensor
“thinks” the current ambient light
level = night, because the lights will
turn on low at 20% wattage.
Factory setting: Night Only

• Sensitivity: Increases or decreases
the responsiveness and range.

Control Panel:

Turn controls gently. Do not force
past stops.

How Does SmartLantern Work?

Sensitivity

Time Control

Photocell

The SmartLantern

infrared sensor

“sees” small temperature changes
caused by the motion of people or
cars within its Detection Zone and
turns on lights automatically. It 
welcomes visitors and may deter
intruders.

How long do the lights stay on?

Lights remain on as long as there is
movement within the Detection Zone.
In Hi/Lo Model, lights revert to dim.
Once the zone is vacated, lights can
be adjusted to remain on approxi-
mately 5 seconds up to 15 minutes.

The Hi/Lo Model will keep lights on at
20% wattage from dusk until dawn
and then brightens to full wattage
when movement is detected.

Will the sensor detect animals?

SmartLantern may detect large 
animals. Having animals trigger the
sensor can give property a “lived-in”
look.You can limit animal detection
by placing opaque weatherproof tape
on the lower part of the lens or using
the bottom mask on the Lens Mask
Kit provided.

What does Manual Override do?

Keep  lights on by flipping the wall
switch two times within 5 seconds.
Sensor resets to auto mode at
dawn. No extra wiring needed.

8

Choosing A Location

Location Considerations:

• Choose a location from which the
sensor can “see” all the parts of
movement that will be illuminated by
its lights.

• SmartLantern may be painted to
blend with existing house color.
Carefully apply masking tape to the
sensor lens or use the Lens Mask Kit
provided before painting!

• Sensor functions best when the
direction of expected movement is
across its detection pattern, not
towards the sensor.

• If wall mounting, locate 5’-8’ high for
optimum range. Lower mounting
height will reduce range.

• The sensor has a “Double Look
Down” Lens with one “Look Out”
zone and two “Look Down” zones for
excellent detection at both long and
close range.

Top View

Look Down  30’
Zones

30’

8’

Side View

60’

Detection Pattern:

• Detection extends out a maximum
of 30 feet and is 180º wide.

• To reduce the Detection Pattern
length, adjust the tilt set screw under-
neath the sensor using the hex
wrench provided.

• To reduce Detection Pattern
width, mask the sides of lens with
opaque weatherproof tape or lens
mask kit.

• If sensor is mounted by a doorway
at the top of stairs, be aware that
the elevated mounting height may
extend the sensor’s range.

Tilt Set Screw

Mounting Plates:

To order mounting plates without arm
extender and sensor:

Catalog # Description
DUM1       Straight wall mounting plate
DUM2       Clapboard cut mounting plate

If clapboard or straight mounting plates
are used without arm extender and 
sensor, use the white plastic mounting
plate cover to close up the opening on
the bottom of the mounting plate.

Summary of Contents for SL500

Page 1: ...econd test time for fast installa tion Works day or night No Hands Auto Testing Auto mode starts after 3 minutes of testing Built for Severe Conditions Double weatherproofing for long life Photoelectr...

Page 2: ...F POWER BY REMOVING POWER FUSE OR TURNING OFF CIRCUIT BREAKER BEFORE INSTALLATION Total lighting load must not exceed Relay On Off Model 5 amps 500 watts incandescent quartz or 250 watts fluorescent a...

Page 3: ...8 Twist on wire nuts Secure with electrical tape 9 Fasten lantern and mounting plate to box using lantern mounting nipple and crossbar provided Use silicone sealant around all openings 10 Screw in li...

Page 4: ...g animals trigger the sensor can give property a lived in look You can limit animal detection by placing opaque weatherproof tape on the lower part of the lens or using the bottom mask on the Lens Mas...

Page 5: ...le at 30 feet several steps will be necessary Technical Tips Lights Do Not Turn Off 1 Make sure sensor is not aimed at something that would move or change temperature such as waving branches water air...

Page 6: ...me lantern s shiny metal or glass surfaces will allow reflections to be seen by the sensor Solution Adjust Photocell Control slightly clockwise toward the sun symbol This allows the sensor to function...

Page 7: ...detecting them 4 Make sure sensor is located below and as far as possible from its lights Heat from the lights may trig ger the sensor Solution Move sensor below and away from the lights 5 Make sure...

Page 8: ...e SmartLantern is designed to detect people or cars in the detection area It should not be construed as a theft or crime prevention device RAB does not accept responsibility for any damages resulting...

Reviews: