RAB A17 Instructions Manual Download Page 7

PROGRAMMING GUIDELINES

INSTRUCTIONS

REMOTE-OD

REMOTE-OD

REMOTE CONTROL - IN  - 0322
73724-RAB

1. 

 If you want to send a setting, it will only work if the remote control is on. If you do not 
press any button within 10 seconds, the indicator light will go out. 

2.  

When using “ON/OFF” button, the rest of the buttons except the “ON/OFF”, 

“BRIGHTNESS” and “SEND” buttons will be disabled.

3. 

 When using “TEST” button, the rest of the buttons except the “TEST”, “SENSITIVITY” and 

“SEND” button will be disabled. 

RAB Lighting is committed to creating high-quality, affordable, well-designed and energy-efficient LED lighting and controls that make it easy for electricians to install 

and end users to save energy. We’d love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: [email protected]

4.

 Every change requires you to press the “SEND” button to save. 

5. 

 Because of the power supply DIMMING ratio diff erence, when using diff erent power, 
“BRIGHTNESS” and “STANDBY DIM” adjust percentage of the power will have diff erence 

with the measured power.

Easy Answers

rablighting.com

Visit our website for product info

Tech Help Line

Call our experts: 888 722-1000

e-mail

Answered promptly - [email protected]

Free Lighting Layouts

Answered online or by request

© 2022 RAB LIGHTING Inc.

ON/OFF

 (Long press the “ON/OFF” button until the brightness indicator light is on (First-row). 

Press to turn on or turn off  the fi xture.)

BRIGHTNESS

 (Press to adjust dimming level 70%/80%/90%/100%. pre-set) 

Note: MVS Sensor Brightness factory setting is 100%.

SEND

 (Press to save settings after each change. The indicator light confi rms the save setting.)

HOLD TIME

(Press to ajust hold time 10s/1min/10min/30min.)

Note: MVS Sensor  factory setting hold time is 1 minute.

DAYLIGHT

 (Long press the button until the daylight indicator light is on. Press to adjust daylight threshold

 10lx/30lx/50lx/100lx.) 

Note: MVS Sensor daylight threshhold factory setting is disabled.

SENSITIVITY

 (Press to adjust sensitivity 20%/50%/75%/100%.) 

Note: MVS Sensor sensitivity factory setting is 50%.

STANDBY DIM

 (Press to adjust stand-by dimming level 10%/20%/30%/50%.)

Note: MVS Sensor standby dimming level  factory setting is 20%

STANDBY TIME

 (Press Standby Dim to adjust time + 

∞ / 

1min, 30min, 60min).

Note:  With Daylight activated , choose: 
• Unlimited stand-by time (+ 

): Default mode: light control, turn on/off : choices: 10/50 lux, 30/100 lux   

  100/200 lux; or

• Light threshold mode choices: 10 lux, 30 lux, 100 lux (if light level is 

< preset lux and motion is detected,

   light will turn on at present lux).            

   

note: MVS Sensor standby dimming level factory setting is 1 minute.

RESET

 (Press “RESET” button, products with DIP switch will be controlled by DIP switches; Otherwise all the 

setting will change is Brightness 70%/ Hold time 10s/Sensitivity 20%/ Daylight threshold disable/ Stand-by 
dimmer level 10%/ Stand-by time + 

 .

TEST

The button “TEST” is for testing purpose after debugging. Pressing this button, the sensor goes to test 

mode (hold time is only 3s).

Press to increase the brightness (0%-100%).

Press to reduce the brightness (100%-0%).

Remote Display Area

REMOTE-OD

Button Setting Area

BRIGHTNESS

 (70%/80%/90%/

100%

)

DAYLIGHT

 (10lx/30lx/50l/100lx)

STANDBY DIM

 (10%/20%/30%/50%)

HOLD TIME

 (10S/1min/10min/30min)

SENSITIVITY

 (20%/50%/75%/100%)

STANDBY TIME

 (+ 

/1min/30min/60min)

TEST

SEND

ON/

OFF

+

Summary of Contents for A17

Page 1: ...RS Suitable for wet locations MOUNTING THE UNIVERSAL ARM ON THE FIXTURE 1 Remove the Arm Cover from the Arm by loosening Arm Cover Screws as shown in Fig 1 2 Feed wires from xture into Arm 3 Line up A...

Page 2: ...These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation operation or maintenance 0 10V DIMMABLE WIRING Universal vol...

Page 3: ...r maintain while fixture is energized 1 Clean Polycarbonate lens with non abrasive glass cleaning solution 2 Do not open the xture to clean the LED Do not touch the LED RESPIRATOR Plug Do not open Do...

Page 4: ...x Disable Stand by period 1min 30min 60min Stand by dimming level 10 20 30 50 Microwave frequency 5 8GHz 75MHz Microwave power 0 5mW Detection angle 30 150 Control line Black White 12V Purple DIM Pink...

Page 5: ...2 4 6 8 10 2 4 6 10 12 14 16 8 18 2 4 6 8 10 12 14 16 18 4 3 2 1 1 2 3 4 DETECTION COVERAGE L N Pink Purple Black White 12V LED Driver LED Driver Black White Purple DIM Pink 12V DIM WIRING DIAGRAM He...

Page 6: ...tand by period Stand by dimming level 10 20 30 or 50 Daylight threshold 10Lux 30Lux 50Lux or 100Lux When ambient brightness is lower than preset lux level light automatically turns on When ambient bri...

Page 7: ...SEND Press to save settings after each change The indicator light con rms the save setting HOLD TIME Press to ajust hold time 10s 1min 10min 30min Note MVS Sensor factory setting hold time is 1 minute...

Reviews: