YBLED 40W-60W   INSTALLATION INSTRUCTIONS

® 

Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments. 
Call the Marketing Department at 888-RAB-1000 or email: [email protected]

IMPORTANT

READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE

.

Fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is required for 
safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH 
THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.

 

WARNING: 

Make certain power is OFF before installing or maintaining fixture.

LOCATION

Select a location on a structurally sound, flat wall or pole. Fixture should be located on wall or pole at least 18” below any overhang 

or other structural detail. Fixture must not be recessed.

YBLED Button PC

YBLED 3 pin PCT

YBLED 5 pin PCT

YBLED LC

MOUNTING TO WALL

1.  Secure the fixture to a sturdy wall. Using the mounting 

arm as a guide, mark the 3 mounting holes. Drill 3/16” 

pilot holes and use provided 

Lag Bolts (3) 

to mount to 

wooden surface or use appropriate mounting hardware 

(not supplied) suitable for the mounting surface. 

2.  Install the 2 bottom 

Lag Bolts

 first. Screw in the 

Lag 

Bolts

 so that there is about 3/8” of space under the 

head.

3.  Place the fixture on these 2 bottom 

Lag Bolts

. Install 

the top

 Lag Bolt

 then tighten the other 2 bolts.

4.  Loosen screw and remove the 

Arm Cover.

5.  Knock out the appropriate 

Conduit Knockout

 on the 

Arm Cover

 to route input conduit. Use appropriate 

conduit connectors as required by code. Connect wires 

as shown in wiring diagram. Push all wires back into the 

Housing Arm

. Be careful not to pinch wires.

6.  Secure the 

Arm Cover

 and tighten screw.

7.  Apply weatherproof silicone sealant around the edge 

of the 

Housing Arm

 and the wall. This is especially 

important with an uneven wall surface. 

YARM24 MOUNTING

1.  Secure the

 Interlocking Mounting Clamps

 around the 

YARM24

 using the provided truss screws, locknuts and 

hex-nuts.

2.  Mount the 

YARM24

 to a sturdy wall. Using the 

YARM24

 

mounting plate as a guide, mark the 4 mounting holes. 

Drill 3/16” pilot holes and use provided 

Lag Bolts (4) 

to 

mount to wooden surface or use appropriate mounting 

hardware (not supplied) suitable for the mounting 

surface.  

3.  Remove the 

Arm Cover

 by loosening the screw. Remove 

the 

Clamp

 by loosening the 2 screws on the 

Clamp

.

4.  Knock out the arm-entry knockout on the 

Arm Cover

Secure the 

YARM24

 and the 

Clamp

 in the 

Housing Arm 

and tighten the clamp screws.

5.  Knot wires in 

YARM24

 for strain relief and feed wires 

from the 

YARM24

 into the 

Housing Arm

. Make the 

necessary wiring connections in the 

Housing Arm

Connect wires as shown in wiring diagram. Push all wires 

back into the 

Housing Arm

. Be careful not to pinch 

wires.

6.  Secure 

Arm Cover

 and tighten the screw.

Lag Bolts (3)

Arm Cover

Conduit Knockout