TROUBLESHOOTING 

1.  Check that the line voltage at fi xture is correct. Refer to 

wiring directions.

2.  Is the fi xture is grounded properly?
3.  Be sure the photocell, if used, is functioning properly.

CLEANING & MAINTENANCE

CAUTION: Be sure fi xture temperature is cool enough 

to touch.  Do not clean or maintain while fi xture is 

energized.

1.  Clean glass lens with non-abrasive glass cleaning 

solution.

2.  Do not open fi xture to clean the LED.  Do not touch the 

LED.  

ON-OFF WIRING

Universal voltage driver permits operation at 120V to 

277VAC, 50 or 60Hz except fi xtures factory ordered with a 

120V photocell (/PC) and 277V photocell (/PC2). For Junction 

Box Mount, feed wires through silicone wiring plug into the 

junction box.

1. 

Connect the black fi xture lead to the (+) LINE supply lead.

2. 

Connect the white fi xture lead to the (-) COMMON supply 

lead.

3. 

Connect the bare copper Ground wire from fi xture to 

supply ground.

JUNCTION BOX 

1. 

The Junction box has (4) conduit entry points on the 

center of each side and (1) in the center back.

2. 

Mounting Points

 are dimensioned below.

PATENTS:

 

US:

 pat. D634,878, 

CN:

 ZL201030679778.2

4 3/4”

2 3/16”

3 1/2”

1 1/8”

1 1/8”

Mounting Points

Note:  These instructions do not cover all details or variations 

in equipment nor do they provide for every possible situation 

during installation, operation or maintenance.

LIGHT

FIXTURE

(+)LINE

BLACK

(-)COMMON

WHITE

GROUND

GROUND

WPLED10-IN-0715

Easy Installation & Product Help

Tech Help Line

Call our experts 888 RAB-1000

©2015 RAB LIGHTING Inc.

Northvale, New Jersey 07647 USA

rabweb.com

Visit our website for product info

email

Answered promptly [email protected]

PHOTOCELL INSTALLATION

Photocell may be installed in the fi eld. Apply weatherproof 

silicone sealant to all plugs and unused conduit entries.
1.  Remove close up plug on top of the wall mounting box.
2.  Install photocell and wire as per diagram.
3.  Use photocell rated for your supply voltage.

“COM”

PHOTOCELL

WP2FC

LIGHT 

FIXTURE

BLACK

WHITE

PHOTOCELL

Reviews: