background image

WP3 INSTALLATION INSTRUCTIONS 

TROUBLESHOOTING

 

1.  Is the proper lamp is installed? Check the wattage 

and ANSI code on the fi xture label against markings 
on the lamp.  Refer to Replacement Lamp table 
above for verifi cation.

2.  Make sure the lamp is not defective.  Try a lamp 

known to be in operating condition.

3.  Check that the line voltage at fi xture is correct. Refer 

to wiring directions.

4.  Is there voltage at the lamp socket? If there is no 

voltage, check all connections.

5. Is the fi xture grounded properly?

6.  Is the photocell functioning properly (if used)?

ACCESSORIES AND

REPLACEMENT PARTS

Chrome Wire Guard:

    

GDWP3W

Door Frame & Glass:

  

GLWP3F 

(bronze)

     GLWP3FW 

(white)

Factory Installed Photocell: 

“/PC” (120V)

     “/PC2” 

(277V)

     “/PCS” 

(Swivel 

120V)

Quartz Restrike

  

 

“/QR”  HID only

Note:  These instructions do not cover all details or variations 
in equipment nor do they provide for every possible situation 
during installation, operation or maintenance.

WP3-IN-0609

REPLACEMENT LAMPS AND 

BALLASTS

 Lamp

 ANSI 

Ballast 

Wattage Catalog# Code 

Catalog#

High Pressure Sodium

250 LHPS250 

S50 

BHPSH250QT

Metal Halide

200 Pulse St  LMH200PSQ  M136 

BMHH200PSQ

250 Pulse St  LMH250PSQ  M138 

BMHH250PSQ

Compact Fluorescent 

Base Type

120 LCFL120 

2G8-1 

 

BCLF120

RAB fi xture designs are protected under U.S. and International 
Intellectual Property laws.  Patent Pending.

-*()5

'*9563&

 -*/&

#-"$,

 $0..0/

8)*5&

(306/%

(306/%

CLEANING & MAINTENANCE

CAUTION: Be sure fi xture temperature is cool 
enough to touch.  Do not clean or maintain while 
fi xture is energized.

1.  Clean glass lens with non-abrasive glass cleaning 

solution.

2.  As lamps age, light output diminishes.  Mass 

relamping at regular intervals ensures full light output 
at the highest effi ciency.

LAMP INSTALLATION

CAUTION: Prior to installing, check that the lamp is 
the correct ANSI type and wattage.  Observe lamp 
manufacturer’s recommendations on lamp operation, 
ballast type and burning positions.

1.  Disconnect power.  Make sure fi xture and lamp are 

cool enough to touch.

2. Loosen 

Door Screws (2)  

from the door frame. A 

small rubber O-ring will retain screws.  Open door. 

3.  Fully insert lamp into socket.

4.  Before closing door, make sure gasket is properly 

seated all around the backbox of the wallpack. Close
the door. Tighten 

Door Screws

.

Door 
Screws

WIRING SCHEMATIC

Reviews: